4. If you are installing a new or replacement ServeRAID adapter that uses a
battery, complete the following steps:
a. Remove the battery from the ServeRAID adapter package or the battery
package.
b. Install the battery and connect the battery to the ServeRAID controller as
instructed in the documentation that comes with the ServeRAID controller
or the battery, or see “Installing a ServeRAID adapter battery on the
remote battery tray” on page 66.
5. Pull the release pin to unlock the retention latch; then rotate the retention latch
to the open position.
6. Align the ServeRAID adapter so that the keys align correctly with the
connector on PCI riser-card assembly 2.
7. Insert the ServeRAID adapter into the connector on the riser-card until it is
firmly seated.
For 2U riser card:
For 1U riser card:
Attention: Incomplete insertion might cause damage to the server or the
adapter.
8. Connect any required cables to the ServeRAID adapter.
Chapter 2. Installing optional devices 65