Symptom Possible cause Problem solution
The pump is
not working
Dry-running protection
has tripped
Wait until there is enough water in the well
for the pump to start automatically
Overcurrent protection
has tripped
Check why the overload occurred. Eliminate the cause.
Wait until the motor cools down andswitch on the
pump using the switch built into the safety box
No power supply
Check that the electrical plug of the pump isproperly
inserted in the electrical socket
Check the fuses in the house and any type ofinstalla-
tion fuses that can cut o the mains supply
Check that there is power in the area around your
home - electricity may be disconnected bythe power
company in a wider area
Abnormal voltage
or voltage drop atstar-
t-up
Check the voltage. Check that the cross-section of the
power supply cable is appropriate
Locking
of the oat
switch
Check that the oat switch has not snagged onthe
well wall or any object
The pump is
running but
giving little or
no water
The pump is running
but gives little or no
water
Odłącz pompę od zasilania elektrycznego. Powyjęciu
pompy ze studni oczyść filtr
Incorrect direction
of rotation of the motor
Swap the two wires of the supply cable on thepower
strip (only for three-phase motors)
Incorrectly connected conductors in the protection
box (only if they have been previously disconnected
by the user). Makethecorrect connection. Commis-
sion thecorrect connection to a service centre