Icare HOME tonometer Instruction manual for health care professionals
ENGLISH
1
www.icare-usa.com
INSTRUCTION
MANUAL
FOR HEALTH CARE
PROFESSIONALS
ENGLISH

Questions and Answers

  • M
    Michelle MillerJul 27, 2025
    How to stop the battery light from flashing on Icare Medical Equipment?
    • A
      Amanda MayJul 27, 2025
      A flashing battery light means the battery is empty. Change the batteries.
  • M
    Mitchell BeckJul 31, 2025
    What does 'Battery SERVICE BATTERY' mean on Icare Medical Equipment?
    • D
      Dawn CopelandJul 31, 2025
      The 'Battery SERVICE BATTERY' message indicates that the battery is soon empty. Prepare to change the batteries.
  • E
    Elizabeth SmithAug 6, 2025
    What to do if the probe base light and measure light are flashing red on my Icare HOME?
    • B
      Benjamin JonesAug 6, 2025
      If the probe base light and measure light are flashing red, it could be due to a) the probe being too far from or too near the eye, or b) probe movement was not perpendicular to the cornea. Press the measurement button again to clear the error message. a) Ensure the correct distance of 4-8mm (5/32-5/16”) between the probe tip and the center of the cornea is set. b) Ensure the probe is perpendicular to the center of the cornea.
  • E
    Emily RandolphAug 10, 2025
    Why is the repeat light flashing on my Icare HOME Medical Equipment?
    • J
      Jake ChenAug 11, 2025
      The repeat light may flash due to: a) Too much IOP deviation during the measurement, because the user did not keep the tonometer stable, or b) The eye was not recognized. Press the measurement button again to clear the error message. a) Repeat the measurement, ensuring stability. b) Do not move the tonometer during the measurements, remove your hand or fingers from the infrared transmitters and sensor, and move the patient’s hair away from his/her temple side of the eye. If the eye still does not get recognized contact the seller to arrange sending the device for service.
  • R
    Ryan JonesAug 16, 2025
    How to fix a solid red probe base light on Icare HOME Medical Equipment?
    • S
      Shirley MillerAug 16, 2025
      A solid red probe base light indicates too much vertical tilt. Press the measurement button again to clear the error message and position the tonometer horizontally, ensuring the probe base light turns green.
  • R
    Robert HendricksAug 21, 2025
    What to do if service light is flashing and probe base is flashing red on Icare HOME Medical Equipment?
    • H
      Hannah BryantAug 21, 2025
      If the service light is flashing and the probe base is flashing red, this indicates an incorrect or dirty probe or probe base. Change the probe, clean or change the probe base or contact the seller to arrange sending the device for service.

Summary

Safety Instructions

General Warnings and Handling

Essential warnings, handling precautions, and hygiene guidelines for tonometer use.

Regulatory and Operational Safety

Regulatory and Operational Safety

Covers regulatory compliance, equipment warnings, and patient handling precautions.

EMC and Device Precautions

Indications for Use

Contraindications

Setting Up the Tonometer

Setting Up the Tonometer

Loading the Probe

Procedure for loading a single-use probe into the tonometer for measurement.

Using the Tonometer

Adjusting Measurement Position

Guide on setting the correct distance and alignment for accurate measurements.

Measurement Steps

Continues the step-by-step guide for taking measurements.

Using the Tonometer

Using the Tonometer

Taking Measurements

Instructions on how to perform intraocular pressure measurements.

Reading Measurement Data

Troubleshooting

Error Indicators and Solutions

Explains error indicators and their corresponding reasons and actions.

Maintenance Procedures

Technical and Performance Data

Electromagnetic Declaration

Appendix 1: HCP Training Procedures

Appendix 1: HCP Training Procedures

Appendix 1: HCP Training Procedures

HCP Training: Testing and Certification

Details test measurements and certification criteria for HCPs.

Appendix 2: Patient Training Procedures

Appendix 2: Patient Training Procedures

Appendix 2: Patient Training Procedures

Icare HOME Specifications

General IconGeneral
Device TypeTonometer
TechnologyRebound tonometry
Power SupplyRechargeable battery
Intended UseHome monitoring of intraocular pressure (IOP)
Measurement TimeApproximately 1 second per measurement