Michelle MillerJul 27, 2025
How to stop the battery light from flashing on Icare Medical Equipment?
- AAmanda MayJul 27, 2025
A flashing battery light means the battery is empty. Change the batteries.
How to stop the battery light from flashing on Icare Medical Equipment?
A flashing battery light means the battery is empty. Change the batteries.
What does 'Battery SERVICE BATTERY' mean on Icare Medical Equipment?
The 'Battery SERVICE BATTERY' message indicates that the battery is soon empty. Prepare to change the batteries.
What to do if the probe base light and measure light are flashing red on my Icare HOME?
If the probe base light and measure light are flashing red, it could be due to a) the probe being too far from or too near the eye, or b) probe movement was not perpendicular to the cornea. Press the measurement button again to clear the error message. a) Ensure the correct distance of 4-8mm (5/32-5/16”) between the probe tip and the center of the cornea is set. b) Ensure the probe is perpendicular to the center of the cornea.
Why is the repeat light flashing on my Icare HOME Medical Equipment?
The repeat light may flash due to: a) Too much IOP deviation during the measurement, because the user did not keep the tonometer stable, or b) The eye was not recognized. Press the measurement button again to clear the error message. a) Repeat the measurement, ensuring stability. b) Do not move the tonometer during the measurements, remove your hand or fingers from the infrared transmitters and sensor, and move the patient’s hair away from his/her temple side of the eye. If the eye still does not get recognized contact the seller to arrange sending the device for service.
How to fix a solid red probe base light on Icare HOME Medical Equipment?
A solid red probe base light indicates too much vertical tilt. Press the measurement button again to clear the error message and position the tonometer horizontally, ensuring the probe base light turns green.
What to do if service light is flashing and probe base is flashing red on Icare HOME Medical Equipment?
If the service light is flashing and the probe base is flashing red, this indicates an incorrect or dirty probe or probe base. Change the probe, clean or change the probe base or contact the seller to arrange sending the device for service.
Device Type | Tonometer |
---|---|
Technology | Rebound tonometry |
Power Supply | Rechargeable battery |
Intended Use | Home monitoring of intraocular pressure (IOP) |
Measurement Time | Approximately 1 second per measurement |
Essential warnings, handling precautions, and hygiene guidelines for tonometer use.
Covers regulatory compliance, equipment warnings, and patient handling precautions.
Procedure for loading a single-use probe into the tonometer for measurement.
Guide on setting the correct distance and alignment for accurate measurements.
Continues the step-by-step guide for taking measurements.
Instructions on how to perform intraocular pressure measurements.
Explains error indicators and their corresponding reasons and actions.
Details test measurements and certification criteria for HCPs.