Troubleshooting errors on Pelletizer PR750H and PR350H.
TAG NAME ID : 33
Emergency stop activated.
www.icetechworld.com | IceTech Dry Ice Technology | Rev 2
Tag name ID 33
Emergency stop activated.
1. Check if the emergency stop button is
activated.
Yes, the emergency stop button is
activated.
Release emergency stop button.
Reset and restart
the Pelletizer.
No, there is no problems. Go to point 2
2. Check if the emergency stop button is
damaged.
Yes, the emergency stop button
is damaged.
Replace or repair the emergency
stop button.
Reset and restart
the Pelletizer.
No, there is no problems.
? Contact IceTech
technical support.