Troubleshooting errors on Pelletizer PR750H and PR350H.
TAG NAME ID : 2+3+4+5+6+7+8+9
Extruder 1 or 2 max. Time forward exceeded
ALARM CODES No. :
A120 + A130 + A1600 + A1700
B120 + B130 + B1600 + B1700
www.icetechworld.com | IceTech Dry Ice Technology | Rev 2
Tag name ID 2+3+4+5+6+7+8+9
Extruder 1 or 2 max. time
forward exceeded.
Alarm codes no
A120+A130+A1600+A1700
B120+B130+B1600+B1700
1. There could be a mechanical problem
inside the extruder cylinder or hydraulic
cylinder.
Remove one of the dies and move the die
changer to this position in "Single mode".
Check the extruder for internal mechanical
wear.
Yes, there is a mechanical problem or
wear in the extruder cylinder.
Repair or replace the component
which are broken or worn out.
Reset and restart
the Pelletizer.
No, there is no problems. ? Contact IceTech technical support.