Tag name ID
10+11+12+13+14+15+16+17
Extruder 1 or 2 max hydraulic
pressure return exceeded.
Alarm codes no
A160+B160+A1300+B1300
A2000+B2000+A2500+B2500
1. There could be a build up of dry ice
inside the extruder cylinder behind the
extruder piston.
Remove the degassing boxes and filters.
In "Single mode" drive the piston forward
until the pistonring appears.
Check the piston ring and piston for
mechanical wear.
Yes, the piston ring or piston i
s worn or damaged.
Replace the component which are
broken or worn out.
Reset and restart
the Pelletizer.
No, there is no problems. ? Contact IceTech technical support.