Troubleshooting errors on Pelletizer PR750H and PR350H.
TAG NAME ID : 18
Max oil temperature exceeded.
www.icetechworld.com | IceTech Dry Ice Technology | Rev 2
Tag name ID 18
Max oil temperature exceeded.
1. The temperature of the hydraulic oil is to
high above 70°C (158°F).
The error cannot be reset until the
temperature has fallen below 50°C (122°F).
Check oil level.
Yes, the oil level is low.
Refill with the necesarry amount of
oil.
Reset and restart
the Pelletizer.
No, there is no problems. Go to point 2
2. The temperature of the hydraulic oil is
to high above 70°C (158°F).
The error cannot be reset until the
temperature has fallen below 50°C
(122°F).
Check oil quality.
Yes, the oil quality is not
satisfiying. It is contaminated.
Change the hydraulic oil according to
procedure no. 14
Reset and restart
the Pelletizer.
No, there is no problem. Go to point 3
3. The temperature of the hydraulic oil is
to high above 70°C (158°F).
The error cannot be reset until the
temperature has fallen below 50°C
(122°F).
Check oil temperature transmitter and
wire connections.
Yes, the oil temperature
transmitter is not working.
Replace the transmitter
or repair the wire
connections.
Reset and restart
the Pelletizer.
No, there is no problems. ? Contact IceTech technical support.