Parts Diagrams
Battery
Compartment
Mode
Switch
Freeze
Switch
High Temp.
Switch
Specifications
Electrical rating: •Millivoltto30VAC/VDC
•DCPower:3.0VDC(2“AA”alkalinebatteriesincluded)
•1ampmaximumperterminal
•2ampmaximumtotalload
Temperature control range: 45°Fto90°FAccuracy:±1°F
Back Light:NotavailableonNandVNmodels
Differential Rage:1°Fto3°F
System congurations:1-stageheat,gas,andoil
Terminations:R,W,S1,S2
Important Safety Information
WARNING!
:
Always turn off power at the main power supply before installing, cleaning,
or removing thermostat.
• Thisthermostatisfor24VACapplicationsonly;donotuseonvoltagesover30VAC
• Donotshortacrossterminalsofgasvalveorsystemcontroltotestoperation;thiswilldamageyour
thermostatandvoidyourwarranty
• Allwiringmustconformtolocalandnationalelectricalandbuildingcodes
• Usethisthermostatonlyasdescribedinthismanual
Package Contents/Tools Required
Package includes: SC1600thermostatonbase,thermostatcover,wiringlabels,screwsandwall
anchors,Installation,OperationandApplicationGuide.
Tools required for installation:Drillwith3/16”bit,hammer,screwdriver.
Manual Changeover
Non-Programmable
Battery
SC1600L/VL
Non-Programmable Electronic Thermostat
Installation, Operation & Application Guide
For more information on our complete range of American-made
products – plus wiring diagrams, troubleshooting tips and more,
visit us at www.icmcontrols.com
Controls Single Stage Heating Systems
Millivolt and Hydronic (water or steam) System Compatible
Compatible with Gas and Oil Systems
Backlit Display
Mercury-Free,
Environmentally Safe
To Remove Existing Thermostat
ELECTRICAL SHOCK HAZARD
Turn off power at the main service panel by removing
the fuse or switching the appropriate circuit breaker to the OFF position before
removing the existing thermostat.
1. Turnoffpowertotheheatingsystembyremovingthefuseorswitchingtheappropriatecircuit
breakeroff.
2. Removecoverofoldthermostat.Thisshouldexposethewires.
3. Labeltheexistingwireswiththeenclosedwirelabelsbeforeremovingwires.
4. Afterlabelingwires,removewiresfromwireterminals.
5. Removeexistingthermostatbasefromwall.
6. Refertothefollowingsectionforinstructionsonhowtoinstallthisthermostat.
General Description
The SC1600thermostatisadigital,mercury-free,non-programmable,electronicthermostat.
•Compatiblewithsingle-stageheatingsystems
•Compatibleasamasterthermostatinzonedsystemapplications
•Freeze Protection Feature:Protectspipesfromfreezing!Iftheroomtemperaturedropsto40°F,
thethermostatautomaticallyturnsontheheat;thethermostatmustbe
intheHeatposition;worksevenifthebatteriesaredead
•System Customization:Choosethreeavailabletemperaturedifferentialsettings
ELECTRICAL SHOCK HAZARD
– Turn off power at the main service panel by removing
the fuse or switching the appropriate circuit breaker to the OFF position before
removing the existing thermostat.
IMPORTANT: Thermostat installation must conform to local and national building and electrical
codes and ordinances.
Note: Mount the thermostat about ve feet above the oor. Do not mount the thermostat on
an outside wall, in direct sunlight, behind a door, or in an area affected by a vent or
duct.
1. Turnoffpowertotheheatingsystembyremovingthefuseorswitchingofftheappropriatecircuit
breaker.
2. MovetheOff/HeatswitchintotheOff position.
3. Toremovecover,insertandtwistacoinorscrewdriverintheslotsonthesidesofthethermostat.
4. Putthermostatbaseagainstthewallwhereyouplantomountit(Besurewireswillfeedthrough
thewireopeninginthebaseofthethermostat).
5. Marktheplacementofthemountingholes.
6. Setthermostatbaseandcoverawayfromworkingarea.
7. Usinga3/16”drillbit,drillholesintheplacesyouhavemarkedformounting.
8. Useahammertotapsuppliedanchorsinmountingholes.
9. Alignthermostatbasewithmountingholesandfeedthecontrolwiresthroughwireopening.
10.Usesuppliedscrewstomountthermostatbasetowall.
11. Insertstripped,labeledwiresinmatchingwireterminals.See“WiringDiagrams”sectionofthis
manual.
CAUTION!
:Be sure exposed portion of wires does not touch other wires.
12.Tightenscrewsonterminalblock.Gentlytugwiretobesureofproperconnection.Doublecheck
thateachwireisconnectedtotheproperterminal.
13.Inserttwofresh“AA”alkalinebatteriesintothermostat,orientedinthedirectionshownonthe
batterycompartment.
14.Replacecoveronthermostatbysnappingitinplace.
15.Turnonpowertothesystematthemainservicepanel.
To Install Thermostat
Replacing Wiring Labels
Replacetheoldlabelswiththeenclosed
newlabels.
Old New Type
H,W,4 W Heatingcontrol
M,4,RH,RS,R R Transformer,hotside
N/A S1,S2 Optionalremotesensor