Installation, Operation & Application Guide
For more information on our complete range of American-made
products – plus wiring diagrams, troubleshooting tips and more,
visit us at www.icmcontrols.com
1 Heat/1 Cool
Auto Changeover
Hardwire
SC4011
• Congurable
• Single-StageHeat/CoolSystems
• Single-StageHeatPumpSystems
• LargeDisplayWithBacklight
• SelectableFahrenheitorCelsius
• CompatiblewithGas,Oil,orElectric
• SimpleSet™FieldProgramming
• StatusIndicatorLight
• RelayOutputs
(minimumvoltagedropinthermostat)
• RemoteSensorCompatible
• IdeallySuitedfor:
– Residential (New Construction/Replacement)
– Light Commercial
Non-Programmable Electronic Thermostat
Icon Descriptions
Fan operation icon
Cooling operation icon
Heating operation icon
Lock mode activated
Room temperature
offset activated
Specifications
Electricalrating: • 24VAC(18-30VAC)
•1ampmaximumperterminal
•3ampmaximumtotalload
Temperaturecontrolrange:45°Fto90°F(7°Cto32°C)Accuracy:±1°F(±0.5°C)
Systemcongurations:1-stageheat,1-stagecool,heatpump,gas,oil,electric
Timing:
Anti-shortCycle:
4minutes
Backlight Operation
Terminations:S1,S2,Y,W/O/B,G,RC,RH,C
Package Contents/Tools Required
Packageincludes: SC4011Prothermostatonbase,thermostatcover,wiringlabels,screwsand
wallanchors,Installation,OperationandApplicationGuide
Toolsrequiredforinstallation:Drillwith3/16”bit,hammer,screwdriver
Important Safety Information
WARNING!
:
Alwaysturnoffpoweratthemainpowersupplybeforeinstalling,cleaning,
orremovingthermostat.
• Thisthermostatisfor24VACapplicationsonly;donotuseonvoltagesover30VAC
• Donotshortacrossterminalsofgasvalveorsystemcontroltotestoperation;thiswilldamageyour
thermostatandvoidyourwarranty
• Allwiringmustconformtolocalandnationalelectricalandbuildingcodes
• Donotuseairconditioningwhentheoutdoortemperatureisbelow50degrees;thiscandamage
yourA/Csystemandcausepersonalinjuries
• Usethisthermostatonlyasdescribedinthismanual
To Remove Existing Thermostat
ELECTRICALSHOCKHAZARD
–Turnoffpoweratthemainservicepanelbyremoving
thefuseorswitchingtheappropriatecircuitbreakertotheOFFpositionbefore
removingtheexistingthermostat.
1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingtheappropriate
circuitbreakeroff.
2. Removecoverofoldthermostat.Thisshouldexposethewires.
3. Labeltheexistingwireswiththeenclosedwirelabelsbeforeremovingwires.
4. Afterlabelingwires,removewiresfromwireterminals.
5. Removeexistingthermostatbasefromwall.
6. Refertothefollowingsectionforinstructionsonhowtoinstallthisthermostat.
Parts Diagram
Congurationswitch
Reset switch
Left(system)
button
Right (fan)
button
Down button
Upbutton
Field programming pins
RC/RH Jumper
S1 RHRCY
W
O/B
G CS2
RESET
CONFIG
FP
RH
RC
To Install Thermostat
ELECTRICALSHOCKHAZARD
–Turnoffpoweratthemainservicepanelbyremoving
thefuseorswitchingtheappropriatecircuitbreakertotheOFFpositionbefore
removingtheexistingthermostat.
IMPORTANT: Thermostat installation must conform to local and national building and electrical
codes and ordinances.
Note: Mount the thermostat about ve feet above the oor. Do not mount the thermostat on an
outside wall, in direct sunlight, behind a door, or in an area affected by a vent or duct.
1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingtheappropriate
circuitbreakeroff.
2. Toremovecover,pullgentlyattheseamatthetop.
3. Putthermostatbaseagainstthewallwhereyouplantomountit(Besurewireswillfeedthrough
thewireopeninginthebaseofthethermostat).
4. Marktheplacementofthemountingholes.
5. Setthermostatbaseandcoverawayfromworkingarea.
6. Usinga3/16”drillbit,drillholesintheplacesyouhavemarkedformounting.
7. Useahammertotapsuppliedanchorsinmountingholes.
8. Alignthermostatbasewithmountingholesandfeedthecontrolwiresthroughslitinthermal
intrusionbarrierandintowireopening.
9.Usesuppliedscrewstomountthermostatbasetowall.
10.For2transformersystems,removeanddiscardRC/RHjumper.
11.Insertstripped,labeledwiresinmatchingwireterminals.
CAUTION!: Be sure exposed portion of wires does not touch other wires.
12.Gentlytugwiretobesureofproperconnection.Doublecheckthateachwireisconnectedtothe
properterminal.
13.Turnonpowertothesystematthemainservicepanel.
14.Congurethermostat(seeCongurationModeSetting4)tomatchthetypeofsystemyouhave.
15.Replacecoveronthermostatbysnappingitinplace.
16.Testthermostatoperationasdescribedin“TestingtheThermostat”.
Hardwired
3-Wire,SingleTransformer
Hardwired
4-Wire,SingleTransformer
Wiring Diagrams
Hardwired
5-Wire,TwoTransformer
(Both transformers must be in phase)
Hardwired
4or5-Wire,SingleTransformer
Fan
Control
IMPORTANT:Beforewiring,removepre-installed
RC/RHjumper.
Hardwired
CoolorHeatActiveReversingValve
Hardwired
4-Wire,SingleTransformer
Remote or Outdoor Sensor Installation (Optional)
1. Removecoverfromremotesensorhousing.
2. Selectanappropriatelocationformountingtheremotesensor.
3. Mountremotesensorunitusinghardwareprovided.
4. Installtwostrandshieldedwirebetweenremotesensorandthermostat.Shieldedwiremustbe
used.Donotrunremotesensorwireinconduitwithotherwires.
•Wire1shouldrunbetweentheS1terminalonthethermostatandtheS1terminalontheremote
sensor
•Wire2shouldrunbetweentheS2terminalonthethermostatandtheS2terminalontheremote
sensor
•ConnecttheshieldingofthewiretotheS2terminalonthethermostat
5. Congurethethermostattooperatewiththeremotesensor(seeCongurationModesetting10).
Note: Remote or outdoor sensor reading can be displayed by
simultaneously pressing the Down and SYS buttons.
Remote Sensor: (Shown: Optional ICM ACC-RT103 Remote Indoor
Sensor; for outdoor sensor, order ACC-OD103.)
Press the up or downbuttontochangesettingswithineachscreen.
Down
button
Up
button
Toexitcongurationmode,presstheCONFIGswitchfor1second.
Press the rightbuttontoadvancetothenextscreen.
Note: Pressing the
left
button will return you to the previous screen.
Left
button
Right
button
Configuration Mode
OFF
1. VerifytheSC4011Prois in the OFFmode.
Press the SYS(left)buttonuntiloffmodedisplays.
2. Removethecoverofthethermostatbygentlypullingnearoneofthecornersatthetopofthe
thermostat.
ThecongurationmodeisusedtosettheSC4011Protomatchyourheating/coolingsystem.The
SC4011Profunctionswithheatpump,airconditioning,gas,oilorelectricheatsystems.
Tocongurethe SC4011Pro,performthefollowingsteps:
3. PresstheCONFIGbuttonfor1secondwhiletheSC4011Prois in OFF
mode.
CONFIG
Configuration Mode Settings
ThesetupscreensforCongurationModeareasfollows:
2.TemperatureDifferential(1°Fto5°F)(0.5°Cto2.5°C)
Setthenumberofdegreesbetweenyour“setpoint”temperatureandyour
“turnon”temperature.
Press the up or down buttontosetdifferentialvalue.
Press the rightbuttontoadvancetothenextscreen.
1.TemperatureScale(F or C)
ChooseFahrenheitorCelsius.
Press the up or down buttontoselect.
Press the
right
buttontoadvancetothenextscreen.
3.Deadband(1°F-9°F)(1°C-5°C)
Settheminimumnumberofdegreesbetweenyourheatsetpointandyour
coolsetpointinAutochangeovermode.
Press the up or down buttontosetdeadbandvalue.
Press the right buttontoadvancetothenextscreen.
5. Lockout(0-8°,COOL-HEAT)
Select the number of degrees set temperature can be changed during
keypadlockout.COOL-HEATlockoutallowsadjustmentoftheset
temperaturestothemaximumheatsettemperatureselectedinStep6and
minimumcoolsettemperatureselectedinStep7.
Note: The mode cannot be changed when the thermostat is locked.
Press the up or down buttontoselect.
Press the right buttontoadvancetothenextscreen.
6. MaximumHeatSetpoint(45°Fto90°F)(7°Cto32°C)
Adjusttocontrolthemaximumheatsettemperatureallowed.
Press the up or down buttontoselect.
Press the right buttontoadvancetothenextscreen.
7. MinimumCoolSetpoint(45°Fto90°F)(7°Cto32°C)
Adjusttocontroltheminimumcoolsettemperatureallowed.
Press the up or down buttontoselect.
Press the right buttontoadvancetothenextscreen.
Choose System
ReversingValve
Active
NumberofCompressors
orCompressorStages
Typeof
Heat
HeatPump
HP O 1
HP b 1
Non-Heat
Pump
Heat Gas
Heat Electric
Press the up or downbuttontoselect.
Press the rightbuttontoadvancetothenextscreen.
4. System–Setforheatpump,non-heatpump,reversingvalveoperationandnumberof
compressorsinyoursystem.
8. RoomTemperatureOffset(+9°Fto-9°F)(+4.5°Cto-4.5°C)
Adjusttocalibratedisplayedroomtemperaturetomatchactualroom
temperature.
Note: When not set to 0, will display.
Press the up or down buttontoselect.
Press the right buttontoadvancetothenextscreen.