5-11 RECEIVE SENSITIVITY ADJUSTMENTS
1) Select an adjustment item (band) using [2]
/ [8].
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push the [BAND] to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
ITEM
OPERATION VALUE
RECEIVE
SENSITIVITY
NOTE:
RECEIVE SENSITIVITY must be adjusted before S-METER. Otherwise, S-METER will
not be adjusted properly.
[Tr]
1 1) Set the power supply voltage to 7.4 V.
2) Connect an SSG to the antenna connector and set as;
Modulation : 1 kHz
Deviation : 3.5 kHz
Push
[BAND].
(Automatic
adjustment)
[30.1 MHz*]
2 Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[49.9 MHz*]
3 Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[50.1 MHz*]
4 Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[75.9 MHz*]
5 Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[76.1 MHz*]
6 Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[90.2 MHz*]
7 Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[117.9 MHz*]
8 Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[118.1 MHz*]
9 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –3 dBµ (–110 dBm)
[146.1 MHz*]
10 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : –3 dBµ (–110 dBm)
[173.9 MHz*]
11 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : –3 dBµ (–110 dBm)
[174.1 MHz*]
12 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[222.1 MHz*]
13 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[259.9 MHz*]
14 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[260.2 MHz*]
15 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[305.2 MHz*]
16 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[349.9 MHz*]
17 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
[350.1 MHz*]
18 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : –3 dBµ (–110 dBm)
[440.1 MHz*]
19 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : –3 dBµ (–110 dBm)
; This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
*; This frequency is an example only, and may differ from the actual frequency displayed on the function display.