Loading...
5 - 12
5-12 S-METER ADJUSTMENT
1) Select an adjustment item using [2]
/ [8].
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push the [BAND] to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
ITEM
OPERATION VALUE
S-METER CURVE
NOTE:
RECEIVE SENSITIVITY must be adjusted before S-METER CURVE and S-METER S3 LEVLE.
Otherwise, S-METER CURVE and S-METER S3 LEVLE will not be adjusted properly.
1 1) Set the power supply voltage to 7.4 V.
2) Connect an SSG to the antenna connector and set as;
Modulation : 1 kHz
Deviation : 3.5 kHz
[145.1 MHz* (S0 level)]
[S0]
2 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –8 dBµ (–115 dBm)
Push
[BAND].
(Automatic
adjustment)
[145.1 MHz* (S3 level)]
[S3]
• Set the SSG as;
Level : –6 dBµ (–113 dBm)
[145.1 MHz
*
(Full scale)]
[SF]
• Set the SSG as;
Level : –2 dBµ (–109 dBm)
[87.5 MHz
*
(S0 level)]
[S0]
3 Set the SSG as;
Frequency : (Displayed on the function display)
Deviation : 52.5 kHz
Level : 2 dBµ (–105 dBm)
[87.5 MHz
*
(S3 level)]
[S3]
• Set the SSG as;
Level : 5 dBµ (–102 dBm)
[
87.5
MHz
*
(Full scale)]
[SF]
• Set the SSG as;
Level : 25 dBµ (–82 dBm)
S-METER S3 LEVEL
(FM)
[S3]
1 1) Set the power supply voltage to 7.4 V.
2) Connect an SSG to the antenna connector and set as;
Modulation : 1 kHz
Deviation : 3.5 kHz
[1.01 MHz
*
]
2 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –6 dBµ (–113 dBm)
Push
[BAND].
(Automatic
adjustment)
[15.1 MHz
*
]
3 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –8 dBµ (–115 dBm)
[40.1 MHz
*
]
4 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –6 dBµ (–113 dBm)
[60.1 MHz
*
]
5 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –6 dBµ (–113 dBm)
[220.1 MHz*]
6 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –6 dBµ (–113 dBm)
[305.2 MHz*]
7 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –6 dBµ (–113 dBm)
[435.1 MHz*]
8 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –6 dBµ (–113 dBm)
[535.1 MHz*]
9 Set the SSG as;
Frequency : (Displayed on the function display)
Level : –6 dBµ (–113 dBm)
[800.1 MHz*]
10 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 0 dBµ (–107 dBm)
; This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.