5 - 13
5-12 S-METER ADJUSTMENT (continued)
1) Select an adjustment item using [2]
/ [8].
2) Set the SSG as specifi ed (frequency, deviation and output level).
3) Push the [BAND] to adjust (automatic) and store the adjustment value.
ADJUSTMENT
ADJUSTMENT
ITEM
OPERATION VALUE
S-METER S3 LEVEL
(WFM)
[1.01 MHz
*
]
[S3]
1 • Set the SSG as;
Frequency : (Displayed on the function display)
Deviation : 52.5 kHz
Level : 5 dBµ (–102 dBm)
†
Push
[BAND].
(Automatic
adjustment)
[15.1 MHz
*
]
2 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 3 dBµ (–104 dBm)
†
[40.1 MHz
*
]
3 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 5 dBµ (–102 dBm)
†
[60.1 MHz
*
]
4 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 5 dBµ (–102 dBm)
†
[220.1 MHz*]
5 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 5 dBµ (–102 dBm)
†
[305.2 MHz*]
6 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 5 dBµ (–102 dBm)
†
[435.1 MHz*]
7 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 5 dBµ (–102 dBm)
†
[535.1 MHz*]
8 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 5 dBµ (–102 dBm)
†
[800.1 MHz*]
9 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : 11 dBµ (–96 dBm)
†
†
; This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.
*; This frequency may differ from the actual frequency displayed on the function display.