14
REMOTE CONTROL
Remote control (CI-V) information
D Command table
Cmd�
Sub cmd� Data Description
1A* 06 See p� 23� Send/read the DATA mode setting
07 00/01 Send/read the NTP server access
(00=Terminate, 01=Initiate)
08*
1
00 ~ 02 Read NTP server access result
(00= Accessing, or have not
accessed after Power ON,
01=Succeeded, 02=Failed)
09*
1
00/01 Read the OVF indicator status
(00=OFF, 01=ON)
0A 00 ~ 02 Send/read the Share Pictures
function status
( 00=OFF, 01=ON, 02=ON (Repeat))
L While transmitting the picture
using the DV Fast Data function,
sends ON even if the status is set
to OFF
0B 00/01 Send/read the RPT MONI setting
(00=OFF, 01=ON)
1B* 00 See p� 23�
Send/read the Repeater tone frequency
01 See p� 23�
Send/read the TSQL tone frequency
02 See p� 23�
Send/read the DTCS code and polarity
07 See p� 23�
Send/read the CSQL code (DV mode)
1C 00* 00/01 Send/read the transceiver’s status
(00=RX, 01=TX)
02* 00/01 Send/read the Transmit frequency
monitor (XFC)
(00=OFF, 01=ON)
03*
1
See p� 16� Read the transmit frequency
1E 00*
1
Read number of available TX
frequency band
01*
1
See p� 16� Read TX band edge frequencies
02*
1
Read number of user-set TX
frequency band
03* See p� 16� Send/read the user-set TX band
edge frequencies
1F* 00 See p� 23� SET > My Station >
Send/read the My Call Sign setting
01 See p� 23� CS >
Send/read the UR, R1, R2 setting
02 See p� 23� SET > My Station >
Send/read the TX Message setting
20 00 00* 00/01*
7
Send/read the Auto DV RX Call
signs output
(00=OFF, 01=ON)
01 See p� 24� Output DV RX Call signs for
transceive
02*
1
See p� 24� Read Auto DV RX Call signs
01 00* 00/01*
7
Send/read the Auto DV RX message
output
(00=OFF, 01=ON)
01 See p� 24� Output DV RX message for
transceive
02*
1
See p� 24� Read Auto DV RX message
02 00* 00/01*
7
Send/read the Auto DV RX status
output
(00=OFF, 01=ON)
01 See p� 24�
Output DV RX status for transceive
02*
1
See p� 24� Read Auto DV RX status
Cmd�
Sub cmd� Data Description
20 03 00* 00/01 Send/read the Auto DV RX
GPS/D-PRS data output
(00=OFF, 01=ON)
01 00 See p� 25�
Output DV RX GPS/D-PRS Position
for transceive
01 01 See p� 25�
Output DV RX D-PRS Object status
for transceive
01 02 See p� 26� Output DV RX D-PRS Item status
for transceive
01 03 See p� 26� Output DV RX D-PRS Weather
status for transceive
02 00*
1
See p� 25� Read Auto DV RX GPS/D-PRS
Position status
02 01*
1
See p� 25� Read Auto DV RX D-PRS Object
status
02 02*
1
See p� 26� Read Auto DV RX D-PRS Item
status
02 03*
1
See p� 26� Read Auto DV RX D-PRS Weather
status
04 00* 00/01
Send/read Auto DV RX GPS/D-PRS
message output
(00=OFF, 01=ON)
01 See p� 26�
Output DV RX D-PRS message for
transceive
02*
1
See p� 26�
Read Auto DV RX D-PRS message
status
21* 00 See p� 27� Send/read the RIT frequency
01 00/01 Send/read the RIT setting
(00=OFF, 01=ON)
02 00/01
Send/read the TX setting
(00=OFF, 01=ON)
22 00 See p� 27� Set the DV TX data (Up to 30 byte)
01 00* 00/01 Set the Auto DV RX data output
(00=OFF, 01=ON)
01 See p� 27� Set the DV RX data for transceive
02* 00/01 SET > DV/DD Set >
Send/read the DV Data TX setting
(00=PTT, 01=Auto)
03* 00/01 SET > DV/DD Set >
DV Fast Data
>
Send/read the
Fast Data setting
(00=OFF, 01=ON)
04* 00/01
SET > DV/DD Set > DV Fast Data >
Send/read the GPS Data Speed setting
(00=Slow, 01=Fast)
05* 00 ~ 10
SET > DV/DD Set > DV Fast Data >
Send/read the TX Delay (PTT) setting
( 00=OFF, 01=1sec ~ 10=10sec)
23 00*
1
See p� 27� Read the position status
01*
00/01
GPS > GPS Set >
Send/read the Position Input setting
(00=Internal GPS, 01=Manual)
02* See p� 21� GPS > GPS Set >
Send/read the Manual Position setting
24 00 00* 00/01 Send/read TX output power setting
(00=OFF, 01=ON)
01 00/01
Set the TX output power for transceive
(00=OFF, 01=ON)

Table of Contents

Other manuals for Icom IC-905

Related product manuals