15
REMOTE CONTROL
Remote control (CI-V) information
D Command table
Cmd�
Sub cmd� Data Description
25* See p� 27� Send/read the selected or
unselected VFO frequency
26* See p� 27�
Send/read the selected or unselected
VFO’s operating mode and filter
27* 00 See p� 28� Read the Scope waveform data
( Only when “Scope ON/OFF status”
(Command: 27 10) and “Scope wave
data output” (Command: 27 11) are
set to “ON,” outputs the waveform
data to the controller (PC)�)
10 00/01
Send/read the Scope ON/OFF status
(00=OFF, 01=ON)
11 00/01 Send/read the Scope wave data
output
(00=OFF, 01=ON)
12 00 Send/read the Main or Sub scope
setting
(00=Main (fixed))
13 00 Send/read the Single/Dual scope
setting
(00=Single (fixed))
14 00 00 ~ 00 03
Send/read the Scope Center mode,
Fixed mode, SCROLL-C mode, or
SCROLL-F mode setting
( 00 00=CENTER mode,
00 01=FIX mode,
00 02=SCROLL-C mode,
00 03=SCROLL-F mode)
15 See p� 28� Send/read the Span setting in the
Center mode or SCROLL-C mode
Scope
16 00 01 ~ 00 04 SCOPE > SCOPE SET >
Send/read the Scope Edge
Number setting in the Fixed mode
or SCROLL-F mode
( 00 01=Fixed Edges No�1,
00 02=Fixed Edges No�2,
00 03=Fixed Edges No�3,
00 04=Fixed Edges No�4)
17 00 00/
00 01
Send/read the Scope Hold
function ON/OFF status
(00 00=OFF, 00 01=ON)
19 See p� 28� Send/read the Scope Reference
level setting
1A 00 00 ~ 00 02
Send/read the Sweep speed setting
(00 00=FAST, 00 01=MID, 00 02=SLOW)
1B 00/01 SCOPE > SCOPE SET >
Send/read the Scope during Tx
(CENTER TYPE) setting
(00=OFF, 01=ON)
1C 00 ~ 02 SCOPE > SCOPE SET >
Send/read the CENTER Type
Display setting
( 00=Filter Center,
01=Carrier Point Center,
02=Carrier Point Center (Abs� Freq�))
1D 00 00/
00 01
Send/read the Scope VBW setting
(00 00=NAR, 00 01=WIDE)
1E See p� 29� Send/read the Scope Fixed Edge
frequencies
Cmd�
Sub cmd� Data Description
27* 20 00/01 SCOPE > SCOPE SET >
Send/read Marker Position (FIX
Type/SCROLL Type) setting
(00=Filter Center, 01=Carrier Point)
28 00 00 ~ 08 Transmit the Voice TX Memory
(00=Stop, 01=T1 ~ 08=T8)
*(Asterisk) Send/read data
*
1
Read only data
*
2
Send only data
*
3
In the CW mode, if the [PTT] or an external TX switch is ON, or the
Break-in function is ON, a message will be transmitted as CW code
when you send it from your PC�
*
4
Sending the power ON command (18 01) turns ON the transceiver
when the transceiver is OFF (Standby/Shutdown)�
*
5
To insert a counter, first clear the other channel’s counter
*
6
Set at least 1 GPS sentence to ON�
Up to 4 GPS sentences can be set to ON at the same time�
*
7
Output setting is automatically set to OFF after turning OFF the
transceiver
*
8
In the 10 GHz band, the drain voltage can be read only while
transmitting, because the power amplifier control method is different
from other bands�

Table of Contents