BASIC OPERATION
■ MDC 1200 system operation
The MDC 1200 signaling system enhances your trans-ceiv-
er’s
capabilities. It allows PTT ID*, Emergency signaling, and
receiving Radio Check. Also, the dispatcher can stun and re-
vive transceivers on the system.
An additional feature of MDC 1200 system found in Icom
transceivers is called aliasing. Each transceiver on the system
has a unique ID number. Aliasing allows the substitution of an
alphanumeric name for this ID number. For transmit, you can
use this alias to select a transceiver to call. For receive, the
alias of the calling station is displayed instead of the ID.
*When[PTT]ispushedand/orreleased,thetransceivertransmits
your own station ID.
D Receiving an Emergency Call
qWhenanemergencycallisreceived;
•Beepssound.
•ThecallingstationID(oralias)and“EMGEMG”aredisplayed
alternately.
w
Turn power OFF, change the channel, push [PTT] for re-
plying the call, etc. to stop the beep and display indication.
D Transmitting an Emergency Call
The MDC 1200 system Emergency feature can be accessed
using the [Emergency] key (p. 5). The transceiver will send
an Emergency MDC 1200 system command once or repeat-
edly for a programmed number of times until it receives the
acknowledgement signal.
The emergency call can be transmitted without a beep emis-
sion, and the LCD indication change depends on how emer-
gency is programmed. Ask your dealer for details.
D Receiving a Stun and Revive
The dispatcher can send MDC 1200 system signals that
will stun or revive your transceiver. If a Stun command is
received that matches your station ID, the transceiver will
display“SORRY”(default)andyoucannotreceiveortrans-
mit.WhenaRevivecommandisreceivedthatmatchesyour
station ID, normal operation is restored.