SECTION 1 SPECIFICATIONS
1 - 1
GENERAL
Frequency coverage : 156.020–157.425 MHz (Tx)
156.050–163.275 MHz (Rx)
Mode : 16K0G3E (FM) / 16K0G2B (DSC)
Usable channels : All international, U.S.A and Canadian channels, plus, 10 Weather channels
Power supply requirement : 13.8 V DC ±15 % (negative ground)
Usable temperature range : –20˚C to +60˚C; –4 ˚F to +140 ˚F
Current drain (at 13.8 V DC) : Transmit at 25 W 5.2 A typical
Receive max. audio 1.2 A typical
Antenna connector : SO-239 (50 )
Dimensions (projections not included) : 220(W)×110(H)×109.4(D) mm; 8
21
32(W) × 4
11
32(H) × 4
5
16(D) inch
Weight : 1350 g; 2.97 lb
TRANSMITTER
Output power (at 13.8 V DC) : High 25 W
Low 1 W
Modulation : Variable reactance frequency modulation
Maximum frequency deviation : ±5.0 kHz
Frequency error : ±0.3 kHz
Spurious emissions : Less than 70 dBc
Adjacent channel power : More than 70 dB
Residual modulation : More than 40 dB
Audio harmonic distortion : Less than 10% at 60% deviation
Audio frequency response : +1 dB to 3 dB of 6 dB octave from 300 Hz to 3000 Hz
Microphone impedance : 2 k
RECEIVER
Receive system : Double conversion superheterodyne system
Intermediate frequencies : 1st 21.7 MHz*
1
, 31.05 MHz*
2
2nd 450 kHz
Sensitivity : Less than 10 dBµ at 12 dB SINAD
Squelch sensitivity : Less than 10 dBµ at threshhold
Adjacent channel selectivity : More than 80 dB
Spurious response : More than 80 dB
Intermodulation rejection ratio : more than 80 dB
Hum and noise : More than 40 dB
Audio output power (at 13.8 V DC) : 5.0 W at 10% distortion with a 4 load
Audio frequency responce : +1 dB to 3 dB of 6 dB octave from 300 Hz to 3000 Hz
GPS interface : NMEA0183 Ver. 2.0 or 3.01
*
1
For Channel 70 only, *
2
For other channels
Specifications are measured in accordance with TIA/EIA 603
All stated specifications are subject to change without notice or obligation.