Icom IC-M802 - PLL UNIT (1) Voltage Diagram

Icom IC-M802
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DD
Operation for distress call to ships
22
7
CALL PROCEDURE
2001 NEW 2001 NEW
q Push [DSC] to select DSC watch mode.
w Push [MODE
SET
] to select the DSC menu.
e Rotate [CH] to select Individual, then push
[ENT].
r Rotate [CH] to select Distress, then push
[ENT].
t Rotate [CH] to select the desired pre-programmed
ID, or Manual set, then push [ENT].
When pre-programmed ID is selected, go to
step u.
y
Enter the desired 9-digit MMSI code via the keypad.
The number 0 (zero) cannot be entered for the 1st
digit, as the 1st digit 0 means group code.
u Rotate [CH] to select 1st telecommand, then push
[ENT].
When No information is selected, go to
step !0.
i Rotate [CH] to select the desired pre-programmed
traffic frequency, or Manual set then push
[ENT].
When pre-programmed traffic frequency is se-
lected, go to step !0.
o Enter the desired transmit and receive traffic fre-
quency via the keypad, then push [ENT].
!0 Rotate [CH] to select the desired calling frequency,
then push [ENT].
!1 The call stand-by screen is displayed as follows,
verify the calling condition then push and hold
[CANCEL/CALL] for 1 sec. to start calling.
!2 After the call, wait for an acknowledgement call.
The calling is performed one time only.
RX
J2B
GPS
<
Wait
for
ACK
>
Individual
Lat
34
34'N
Lon135
34'E
12:34
SP
Exit
******
Individual
******
---------
Call
---------
Category:Distress
To:987654321
Traffic:J3E
TX
2134.0kHz
RX
2134.0kHz
Call
Freq:TX
2187.5kHz
RX
2187.5kHz
Write-Menu
Call
******
Individual
******
----
Call
frequency
----
2187.5kHz
4207.5kHz
6312.0kHz
8414.5kHz
12577.0kHz
16804.5kHz
Ç
OKSEL
******
Individual
******
--
Traffic
frequency
---
TX:_2134.0kHz
RX:_2134.0kHz
OKSEL
******
Individual
******
--
Traffic
frequency
---
Manual
set
T:
4567.0kHz
IC-M802-1
R:
4567.0kHz
T:12345.0kHz
IC-M802-2
R:12345.0kHz
Ç
OKSEL
******
Individual
******
---
1st
telecommand
----
J3E
No
information
Ç
OKSEL
******
Individual
******
------
Address
ID
------
987654321
OK
******
Individual
******
------
Address
ID
------
Manual
set
IC-M802-1
123456789
IC-M802-2
123456788
IC-M802-3
123456787
IC-M802-4
123456786
IC-M802-5
123456785
Ç
OKSEL
******
Individual
******
-------
Category
-------
Routine
Safety
Urgency
Distress
Ç
OKSEL
[MODE SET][ENT][DSC]
[FREQ/CH][CH] [F][CANCEL/CALL]
IC-M802_USA.qxd 02.5.30 11:39 Page 22