26
54 0-255
Adjustment of fixture timing to control Pan/Tilt
mechanisms.
Color Timing
55 0-255
Adjustment of fixture timing to control color
mechanisms.
Beam Timing
56 0-255
Adjustment of fixture timing to control beam
mechanisms.
Gobo Timing
57 0-255
Adjustment of fixture timing to control gobo
mechanisms.
34 58
Control:
The settings is effective after remaining the value
unchanged at least 3 seconds
0-39 No function
40~59 Gobo Scroll ON
60~79 Gobo Scroll OFF
80~99 All motor reset
100~119 Pan/TILT reset
120-139 other motor reset
Refresh RateLED)(default 1.2KHz)
140~200
900Hz~1500Hz+10Hz/+1 value
201 2.5KHz
202 4KHz
203 5KHz
204 10KHz
205 15KHz
206 20KHz
207 25KHz
208-255 No function