Chapter 5 I/O Pair Connection
ET-7000 AIO User Manual, Apr. 2009, V1.04, EMH-011-104----------97
5. I/O Pair Connection
The function is used to make a DI to DO pair through the Ethernet. The communication is
based on Modbus/TCP. Once the configuration is done, the ET-7000 can poll remote DI
status and then write to a local DO device constantly in the background.
Using the function, remote DI status can be transmitted to local DO device over the
Ethernet without any programming skill.
Please refer to Sec. 3.5 Pair Connection for more details regarding the configuration of
the I/O pair connection.