*9MPV050F12 *9MPV075F12 *9MPV100J20 *9MPV125L20
General
GasType
Nat L.P. Nat L.P. Nat L.P. Nat L.P.
Transformer Size (VA)
T’stat Heat Anticipator
40
.50
Input(Btuh) Std/Alt. HiFire
Lo Fire
Output(Btuh) Std/Alt. Hi Fire
Lo Fire
Temp. Rise (
°
F) Hi Fire
Lo Fire
50,000
35,000
46,000
32,200
35--65
35--65
75,000
52,500
70,500
48,800
40--70
40--70
100,000
70,000
92,000
64,400
40--70
40--70
125,000
87,500
115,000
80,500
40--70
40--70
Electrical(Volts/Hz) 115/60 115/60 115/60 115/60
RatingPlate Amps 9.5 11.4 14.6 15.4
Gas & Ignition
GasType
Std. Main Orifices (No/Size)
Gas Valve Honeywell
Regulation Type
Manifold Press. Hi Fire (² WC)
Lo Fire (² WC)
Nat.
2/42
VR8205Q
SNAP
3.5
1.7
L.P.
2/54
VR8205Q
SNAP
10.0
4.9
Nat.
3/42
VR8205Q
SNAP
3.5
1.7
L.P.
3/54
VR8205Q
SNAP
10.0
4.9
Nat.
4/42
VR8205Q
SNAP
3.5
1.7
L.P.
4/54
VR8205Q
SNAP
10.0
4.9
Nat.
5/42
VR8205Q
SNAP
3.5
1.7
L.P.
5/54
VR8205Q
SNAP
10.0
4.9
Ignition Type
Hot Surface
Combustion
Flue Outlet Size (Inches)
Std. Outlet Temp (° F)
Comb. Blower (MFD/Volts)
2
<140
4/370
2
<140
4/370
3
<140
4/370
3
<140
4/370
@Blower/ @ Transition Box (Hi Fire)
Std. Pressures (² of WC)
5¢ No Elbows
40¢ +5--90° DWV Elbows
@Blower/ @ Transition Box (Lo Fire)
Std. Pressures (² of WC)
5¢ No Elbows
40¢ +5--90° DWV Elbows
--1.80 / --2.60
--1.30 / --2.30
--1.20 / --1.90
--1.00 / --1.80
--1.80 / --2.60
--1.30 / --2.30
--1.20 / --1.90
--1.00 / --1.80
--1.80 / --2.60
--1.70 / --2.50
--1.20 / --1.90
--1.00 / --1.80
--1.80 / --2.60
--1.70 / --2.50
--1.30 / --2.30
--1.20 / --2.20
Limits& Controls
Rollout Switch (
°
F)
LimitControlSetting (
°
F)
300
260
300
210
300
240
300
190
Furnace Control (Type)
Furnace Control On
(Timed -- secs) Off
Integrated
30 Hi /45 Lo
60,100,140,180
Std. Pressure Sw. (Part No)
(Hi Fire)Blwer Switch Press (Close)
Blower Switch Pressure (Open)
(Lo Fire)Trans Switch Press (Close)
Transition Switch Pressure (Open)
1013515
0.95
0.80
1.70
1.50
1013515
0.95
0.80
1.70
1.50
1013515
0.95
0.80
1.70
1.50
1013166
1.30
1.10
1.80
1.60
High Altitude Pressure Sw. (Part No)
(Hi Fire)Blwer Switch Press (Close)
Blower Switch Pressure (Open)
(Lo Fire)Trans Switch Press (Close)
Transition Switch Pressure (Open)
1013165
0.70
0.55
1.40
1.20
1013165
0.70
0.55
1.40
1.20
1013165
0.70
0.55
1.40
1.20
1013157
0.85
0.70
1.70
1.50
Blower Data
Type & Size
MotorAmps/Rpm
MotorType/H.p.
Filter Type & Size(Permanent -- supplied)
Min.Cool Cap. (Tons)
Max.Cool Cap. (Tons)
11--8
9.8/1050
DC/
1
/
2
16x25x1
1.5
3
11--10
8.9
DC/
3
/
4
16x25x1
1.5
3
11--10
11.2/1150
DC/1
16x25x1
2
5
11--10
11.2/1150
DC/1
16x25x1(2)
2
5
Gas Conversion Kits All Models
Nat to LP NAHA002LP (1172959*)
LP to Nat NAHA002NG (1172961*)
*Order from Service Parts