iDRY Series Heatless Regenerated Dryers: IOM10003-C (Rev. A) 23
High Dewpoint
(as checked by
external sensor)
Purge Valve
Exhaust Silencers
Desiccant
Purge Exhaust Valve
Low Pressure
High Flow
High Temperature
Inlet Valve
Power
Controller
Adjust and ensure correct setting based on table xx
Backpressure due to clog, install new mufflers
Media is fouled, replace new
See Purge Exhaust Valve troubleshooting
Increase to rated pressure
ensure air inlet flow does not exceed dryer capacity
ensure air inlet temperature does not exceed dryer capacity
See Inlet Valve troubleshooting
Ensure that the controller has correct voltage
See controller troubleshooting
High Pressure
Drop
Desiccant
Pre-filter
Post-filter
Capacity
Desiccant screens
Purge Exhaust valve
Replace fouled desiccant
Contaminated inlet pre-filter, replace
Contaminated outlet post- filter, replace
Overflow, ensure air inlet flow does not exceed dryer
capacity
Remove desiccant/screens and clean screens
See purge exhaust troubleshooting
Back pressure
Purge muffler fouled
Vessel screen
Restricted purge piping
Bad Purge Exhaust
Valve
Replace with new
Empty towers, remove screens and clean
Clean
See purge Exhaust Valve troubleshooting
COMPONENT
TROUBLE
POSSIBLE CAUSE
SUGGESTED ACTION
Purge control
Valve
Setting
Damaged
Dirty
ensure proper setting from table xx
replace valve
open full for clean out or dismantle and clean
Purge Exhaust
Valve
Worn seals
Pneumatic
Electrical
Restriction
Install service kit
check pilot valve, pilot air supply, pilot air filter, flow control
valve on actuator
Check power to solenoid valves
Backpressure silencers or mufflers are clogged, install new
muffler elements
Inlet Valve
Worn seals
Pneumatic
Electrical
Restriction
Install service kit
check pilot valve, pilot air supply, pilot air filter, flow control
valve on actuator
Check power to solenoid valves
Backpressure silencers or mufflers are clogged, install new
muffler elements
Outlet Check Valve
Restriction
Damaged Seal
SERVICEABLE ONLY BY QUALIFIED TECHNICIAN
Drain
Application
Electrical
Overloaded with water, check pre-filter and upstream bulk
water separator
Check electrical connections