iDRY Series Heatless Regenerated Dryers: IOM10003-C (Rev. A) 23
High Dewpoint
(as checked by
external sensor)
Exhaust Silencers
Desiccant
Purge Exhaust Valve
Low Pressure
High Flow
High Temperature
Inlet Valve
Power
Controller
Adjust and ensure correct setting based on table xx
Backpressure due to clog, install new mufflers
Media is fouled, replace new
See Purge Exhaust Valve troubleshooting
Increase to rated pressure
ensure air inlet flow does not exceed dryer capacity
ensure air inlet temperature does not exceed dryer capacity
See Inlet Valve troubleshooting
Ensure that the controller has correct voltage
See controller troubleshooting
Desiccant
Pre-filter
Post-filter
Capacity
Desiccant screens
Purge Exhaust valve
Replace fouled desiccant
Contaminated inlet pre-filter, replace
Contaminated outlet post- filter, replace
Overflow, ensure air inlet flow does not exceed dryer
capacity
Remove desiccant/screens and clean screens
See purge exhaust troubleshooting
Vessel screen
Restricted purge piping
Bad Purge Exhaust
Valve
Empty towers, remove screens and clean
Clean
See purge Exhaust Valve troubleshooting
ensure proper setting from table xx
replace valve
open full for clean out or dismantle and clean
Pneumatic
Electrical
Restriction
check pilot valve, pilot air supply, pilot air filter, flow control
valve on actuator
Check power to solenoid valves
Backpressure – silencers or mufflers are clogged, install new
muffler elements
Worn seals
Pneumatic
Electrical
Restriction
check pilot valve, pilot air supply, pilot air filter, flow control
valve on actuator
Check power to solenoid valves
Backpressure – silencers or mufflers are clogged, install new
muffler elements
SERVICEABLE ONLY BY QUALIFIED TECHNICIAN
Overloaded with water, check pre-filter and upstream bulk
water separator
Check electrical connections