6. Error Message
Code
Cause
LED
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E24
E25
E26
E27
LCM Panel Open
Checksum Error
Signal from the coin base was not received when the power was turned on.
Two seconds after activation, the SYSTEM did not wait for the READY signal
from the DEVICE and jumped to the exception.
Two seconds after a transaction, the SYSTEM did not wait for the READY
signal triggered by the DEVICE.
Coil 1 is damaged.
Coil 2 is damaged.
Coil 3 is damaged.
Low level LED is damaged.
Coin separator sensor problem.
The deck is open for over 30 seconds.
Both the first and second group motors cannot be positioned.
The first motor group cannot be positioned. The first motor group might be
damaged, coin or foreign objects might have caused the motor to stuck,
coins are stuck in the coin tube, or the semicircle disk has derailed.
The second motor group cannot be positioned. The second motor group
might be damaged, coin or foreign objects might have caused the motor to
stuck, coins are stuck in the coin tube, or the semicircle disk has derailed.
Broke away or incorrectly positioned coin tubes.
Coins got stuck at the coin separation area or the coin tube opening twice in
a row, causing the HI Level Sensor to fail to detect the coin twice in a row.
“A” Tube Low Level = empty, HI Level = full at setup.
“B” Tube Low Level = empty, HI Level = full at setup.
“C” Tube Low Level = empty, HI Level = full at setup.
5 Red + 2 Red
Red Light
Red Light
1 Red
3 Red + 1 Red
3 Red + 2 Red
3 Red + 3 Red
3 Red + 5 Red
3 Red + 4 Red
5 Red + 1 Red
7 Red
None
None
5 Red
6 Red + 4 Red
None
None
None
E28
E29
“D” Tube Low Level = empty, HI Level = full at setup.
“E” Tube Low Level = empty, HI Level = full at setup.
None
None
E30
E31
“F” Tube Low Level = empty, HI Level = full at setup.
Barcode Reader error.
None
None
Recognition Ver Error
The three sets of LEDs used to distinguish Coin size have been damaged.
E33
E32
None
None
-15-
CC6100