58
www.idealnetworks.net
Measurement details
• ETL verified to meet ANSI / TIA-1152-A Level 2G, IEC 61935-1 Level VI for
500 MHz and 3000 MHz models
User selectable optional measurements
• TCL, ELTCTL, resistance unbalance
• Time Domain NEXT - to locate distance to crosstalk events
• Time Domain Return Loss - to locate distance to impedance mismatch
events
• Optional measurements do not increase test time
Measuring ranges
• Wiring diagram with distance to faults: resolution 10cm
• Length measurement: from 0 to 600m - display resolution: 0.1m
• Resistance measurement range: 0.02 to 200 Ω - display resolution: 0.1 Ω
• Propagation delay measurement range: 1ns to 1s - display resolution: 1ns
• RF measurement details: ISO / IEC 61935-1 Ed 5, ANSI / TIA-1152-A -
display resolution: 0.1dB
Standard warranty
• 12 months for handsets and accessories
• 6 months for batteries
• Optional Sapphire Care Plan service contracts for extended warranties
and calibration for 1, 2, and 3 year terms
Compliance
• IEC 61010-1: 2010 Ed 3 - Safety requirements for electrical equipment for
measurement, control and laboratory use
• EN61326-1: 2013 - Electrical equipment for measurement, control and
laboratory use. EMC requirements.
• EN55011: 2009 + A2: 2010 - Industrial, scientific and medical equipment.
Radio frequency disturbance characteristics.
• ENGl000-4-2: 2009 - Electrostatic Discharge Immunity Test
• EN61000-4-3: 2006 + A2: 2010 - Radiated, radio-frequency,
electromagnetic field immunity test
• EN61000-4-4: 2004 + Al: 2010 - Electrical Fast Transient / Burst Immunity
Te s t
• ENGl000-4-5: 2006 - Surge Immunity Test
• EN61000-4-6: 2009 - Immunity to conducted disturbances, induced by
radio-frequency fields
• EN61000-4-11: 2004 - Voltage dips, short interruptions and voltage
variations immunity tests