54
SERVICING
Esprit - Installation and Servicing
76
FLOW LIMITER REPLACEMENT
77
WATER PRESSURE SWITCH REPLACEMENT
1. Refer to frame 52.
2. Swing the control box down into the servicing
position. Refer to Frame 46.
3. Drain the boiler CH circuit. Refer to Frame 72.
4. Pull off the two electrical connections from the
switch.
5. Pull off the earth connection.
6. Unscrew the water pressure switch.
7. Re-assemble in reverse order.
8. Refill the boiler. Refer to Frame 32.
9. Check operation of the boiler. Refer to Frame 52.
6
4
1. Refer to frame 52.
2. Isolate the mains cold water supply to the boiler.
3. Drain the boiler DHW circuit. Refer to Frame 72.
4. Unscrew the three union connections at the DHW
isolating valve and remove the valve.
5. Remove the circlip retaining the flow limiter.
6. Using a suitable tool, pull the flow limiter from the
valve body.
7. Fit the new flow limiter and reassemble in
reverse order.
8. Refill the boiler. Refer to Frame 32.
9. Check operation of the boiler. Refer to Frame 52.
5
6
5
4
SERVICING

Other manuals for IDEAL he30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL he30 and is the answer not in the manual?

IDEAL he30 Specifications

General IconGeneral
Height700 mm
Output30 kW
Warranty2 years
Boiler typeCombi
MountingWall-mounted
Fuel TypeNatural Gas
ErP Water Heating EfficiencyA
TypeCombi Boiler
Efficiency89%