INSTALLATION
Esprit - Installation and Servicing
FLUE OUTLET
19
FITTING THE WALL MOUNTING PLATE
Screw the wall mounting plate to the
wall using 3 wall plugs (previously
fitted) with the 3 screws provided.
Choose one of the 3 sets of slots in left,
right and centre bank. Ensuring that at
least one of the screws is fitted into a
top slot.
esp8817
Example of fixing
20
MOUNTING THE BOILER
1. Ensure the plastic plugs are removed
from both the CH and DHW connections
before mounting the boiler.
2. Lift the boiler onto the wall mounting plate
(refer to the Introduction section for safe
handling advice), locating it over the top
angled return.
esp8828