E. OPEnTHERM
F. BuILT In FROsT PROTECTIOn
ADVANCED FEATURES
The unit uses the OpenTherm protocol to control the boiler ow temperature set point in central heating operation. This
means that the boiler will run in its most efcient manner and offer signicant savings in energy over standard room
thermostats. It will also give more accurate and comfortable temperature control in the room where it is installed.
If the room temperature is close to its setpoint then the pump may run for extended periods without switching the burner
on. This is normal operation which reduces gas consumption whilst maintaining the desired room temperature.
If the temperature in the room falls below 5ºC, the boiler will re to maintain the minimum 5ºC setpoint regardless of
whether the timer is in an “off” period or not.
204796-6.indd 17 15/12/2011 14:34:25
back

Other manuals for IDEAL LOGIC+ Combi 30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL LOGIC+ Combi 30 and is the answer not in the manual?

IDEAL LOGIC+ Combi 30 Specifications

General IconGeneral
ModelLOGIC+ Combi 30
Boiler TypeCombi
Central Heating Output24.2 kW
Domestic Hot Water Output30.3 kW
Efficiency Rating94%
ErP RatingA
Flow Rate12.4 l/min
Dimensions700x395x278 mm
Fuel TypeNatural Gas
MountingWall Mounted
Warranty7 years
Central Heating Pressure3 Bar