SYMBOL UNITS 15 kW 18 kW 24 kW 30 kW
Condensing Boiler n/a n/a yes yes yes yes
Low Temperature Boiler n/a n/a no no no no
B1 Boiler n/a n/a no no no no
Cogeneration Space Heater n/a n/a no no no no
Equipped with a Supplementary Heater n/a n/a no no no no
Combination Heater n/a n/a no no no no
Nominal Heat Output for Space Heating
Full Load P4 kW 15.1 18.1 24.3 30.3
Part Load P1 kW 4.9 5.9 8.0 9.9
Auxiliary Electricity Consumption
Full Load elmax kW 0.020 0.025 0.044 0.052
Part Load elmin kW 0.003 0.023 0.012 0.012
Standby PSB kW 0.002 0.002 0.002 0.001
Seasonal Space Heating Energy Eciency
Full Load ƞ4 % 90.0 90.0 90.0 89.6
Part Load ƞ1 % 97.8 98.5 98.6 98.2
Standby Loss Pstby kW 0.05 0.05 0.05 0.05
Ignition Pign kW 0 0 0 0
Emissions NOx (Gross) NOx, pond Hs mg/kWh 21 24 28 26
Annual Energy Consumption QHE GJ 47 56 75 93
Sound Power Level, Indoors LWA dB 42 44 50 50
SYMBOL UNITS MODEL
15 kW 18 kW 24 kW 30 kW
Condensing boiler Yes
Seasonal space heating eciency class A
Rated heat output kW 15 18 24 30
Seasonal space heating energy eciency ƞs % 93 93 94 93
Annual energy consumption QHE GJ
47 56 75 93
Sound power level, indoors LWA dB
42 44 50 50