Installation and Servicing
SECTION 2 - INSTALLATION
MENU OPERATION - CONT’D
INSTALLATION
FAULT HISTORY
To view the Fault History of the boiler
press MENU and the following screen
will be displayed.
EXITSELECT
MENU
SERVICE COMPANY NAME
SERVICE COMPANY PHONE NUMBER
SHOW EFFICIENCY LEVEL
Press
MENU
SHOW EFFICIENCY LEVEL
HOT WATER PREHEAT ON / OFF
SERVICE COMPANY PHONE NUMBER
SERVICE COMPANY NAME
MAXOFF
MAXOFF
SELECT EXIT
until the following screen is
displayed.
EXITSELECT
MENU
FAULT HELP
VENT SYSTEM
FAULT HISTORY
CHANGE SERVICE INTERVAL
Press SELECT and a screen similar to
the following will be displayed.
EXITNEXTPREV
FAULT HISTORY
LOW WATER PRESSURE
4
6 DAYS AGO
TOTAL OCCURENCES:
MOST RECENT:
Press
MENU
SHOW EFFICIENCY LEVEL
HOT WATER PREHEAT ON / OFF
SERVICE COMPANY PHONE NUMBER
SERVICE COMPANY NAME
MAXOFF
MAXOFF
SELECT EXIT
and
MENU
SHOW EFFICIENCY LEVEL
HOT WATER PREHEAT ON / OFF
SERVICE COMPANY PHONE NUMBER
SERVICE COMPANY NAME
MAXOFF
MAXOFF
SELECT EXIT
to view the full list.
Press EXIT twice to return to normal
operation.
FAULT HELP
This feature provides a list of potential
corrective actions at an installer level
for all faults detectable by the boiler
electronics Press MENU and the
following screen will be displayed
EXITSELECT
MENU
SERVICE COMPANY NAME
SERVICE COMPANY PHONE NUMBER
SHOW EFFICIENCY LEVEL
Press
MENU
SHOW EFFICIENCY LEVEL
HOT WATER PREHEAT ON / OFF
SERVICE COMPANY PHONE NUMBER
SERVICE COMPANY NAME
MAXOFF
MAXOFF
SELECT EXIT
until the following screen is
displayed.
EXITSELECT
MENU
VENT SYSTEM
SENSOR READINGS
FAULT HELP
FAULT HISTORY
Press SELECT and the following screen
will be displayed.
EXITSELECT
FAULT HELP
IGNITION LOCKOUT
NO WATER FLOW
LOW WATER PRESSURE
Press
MENU
SHOW EFFICIENCY LEVEL
HOT WATER PREHEAT ON / OFF
SERVICE COMPANY PHONE NUMBER
SERVICE COMPANY NAME
MAXOFF
MAXOFF
SELECT EXIT
and
MENU
SHOW EFFICIENCY LEVEL
HOT WATER PREHEAT ON / OFF
SERVICE COMPANY PHONE NUMBER
SERVICE COMPANY NAME
MAXOFF
MAXOFF
SELECT EXIT
until the desired fault is
shown then press SELECT and a screen
similar to the following will be shown.
EXIT
LOW WATER PRESSURE
With boiler o & system cold
fill system to between 1.0 & 1.5 bar
Bleed radiators then refill.
If fault persists contact Ideal (01482 498660)
If pressure loss re-occurs contact installer
Press EXIT swich when nished.
VENT SYSTEM
The Vent System feature aids removal of
air from the heat exchanger. The pump
will be switched on for 50s and then off
for 10s while the diverter valve is moved
between DHW and CH every 30s. The
feature lasts for 5 minutes.
Press MENU and the following screen
will be displayed.
EXITSELECT
MENU
SERVICE COMPANY NAME
SERVICE COMPANY PHONE NUMBER
SHOW EFFICIENCY LEVEL
Press
MENU
SHOW EFFICIENCY LEVEL
HOT WATER PREHEAT ON / OFF
SERVICE COMPANY PHONE NUMBER
SERVICE COMPANY NAME
MAXOFF
MAXOFF
SELECT EXIT
and the following screen is
displayed.
EXITSELECT
MENU
SENSOR READINGS
PUMP / FAN / VALVES
FAULT HELP
VENT SYSTEM
Press SELECT and the following screen
will be displayed.
END
VENT SYSTEM
PUMP SPINS ON 50s, OFF 10s
DIVERTER VALVE ALTERNATES CH/DHW
05:00
MINUTES REMAINING
+30 secs -30 secs
The feature will end automatically after 5
minutes, to end manually press END.