GT3A Series
Timers
805
USA: 800-262-IDEC Canada: 888-317-IDEC
Switches & Pilot Lights Display Lights Relays & Sockets Timers Terminal Blocks
Circuit Breakers
GT3A Series — Analog Timers
Key features of the GT3A series include:
4 selectable operation modes on each model
External start, reset, and pause inputs
Panel mount or socket mount
Large variety of timing functions
Power and output status indicating LEDs
UL, c-UL Listed
File No. E55996
Specifi cations
GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6
Operation Multi-mode Multi-mode with inputs (11 pins)
Time Range 0.1s to 180 hours
Rated Voltage
100 to 240V AC, 50/60Hz
12V DC
24V AC, 50/60Hz / 24V DC
Contact Ratings
125V AC/250V AC, 3A;
30V DC, 1A (resistive load)
125V AC/250V AC, 5A;
30V DC, 5A (resistive load)
Minimum Applicable Load 5V, 10mA (reference value)
Voltage Tolerance
AF20 (100V AC): 85 to 264V AC
AD24: 20.4 to 26.4V AC/21.6 to 26.4V DC
D12: 10.8 to 13.2V DC
Error ±0.2%, ±10 msec (repeat, voltage, temperature)
Setting Error ±10% maximum
Reset Time 60msec maximum
Insulation Resistance 100MW minimum
Dielectric Strength
Between power and output terminals: 2,000V AC, 1 minute
Between contacts of different poles: 2,000V AC, 1 minute
Between contacts of the same pole: 750V AC, 1 minute
Power Consumption
(approximate)
Delayed SPDT
Delayed SPDT +
instantaneous SPDT
Delayed DPDT Delayed DPDT
10.8VA
(200V AC, 60Hz)
13.5VA
(200V AC, 60Hz)
14.4VA
(200V AC, 60Hz)
4.7VA (100V AC, 60Hz),
14.4VA (200V AC, 60Hz)
12VDC/1W
24VDC/0.7W
24VAC/1.2VA
12VDC/1.1W
24VDC/0.6W
24VAC/1.3VA
12VDC/0.8W
24VDC/0.6W
24VAC/1.3VA
Mechanical Life 10,000,000 operations minimum 5,000,000 operations minimum
Electrical LIfe 50,000 operations minimum (rated load) 100,000 operations minimum (rated load)
Weight (approximate) 63g 73g 79g 80g
Vibration Resistance 100m/sec
2
(approximate 10G)
Shock Resistance
Operating extremes: 100m/sec
2
(approximate 10G)
Damage limits: 500m/sec
2
(approximate 50G)
Operating Temperature –10 to +50°C
Operating Humidity 45 to 85% RH
Storage Temperature –30 to +80°C
Housing Color Gray
For information, call 800-221-0487  Switches Unlimited  Fax 718-672-6370  www.switchesunlimited.com
tech@switchesunlimited.com  sales@switchesunlimited.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC GT3A Series and is the answer not in the manual?

IDEC GT3A Series Specifications

General IconGeneral
BrandIDEC
ModelGT3A Series
CategoryTimer