Technical Data
HR9Z-B2192 8/2020 23
Environmental Conditions For Operation
The device complies with class 3K5 and special class 3Z11 as per IEC 60721-3-3 (climatic
conditions):
The device complies with class 3M4 as per IEC 60721-3-3 (mechanical conditions):
The devices complies with the following vibration and shock values as per IEC 60947-1:
Characteristic Value
Maximum installation altitude above mean sea level 2000 m (6562 ft)
Installation required in control cabinet/enclosure with
degree of protection
IP54
Characteristic Value
Ambient temperature -25 ... 55 °C (-13 ... 131 °F), no icing
Rate of change of temperature 0.5 °C/min (0.9 °F/min)
Ambient humidity 5 ... 95 % relative humidity, no condensation
Characteristic Value
Vibration, sinusoidal, displacement amplitude
2 ... 9 Hz
3 mm
Vibration, sinusoidal, acceleration amplitude
9 ... 200 Hz
10 m/s
2
Shock, shock pulse shape: half-sine, peak
acceleration
100 m/s
2
Characteristic Value
Vibration, sinusoidal, displacement amplitude
2 ... 13 Hz
1 mm
Vibration, sinusoidal, acceleration amplitude
13.2 ... 100 Hz
7 m/s
2
Shock, shock pulse shape: half-sine, peak
acceleration
150 m/s
2