Technical Data
22
HR9Z-B2192 8/2020
Environmental Conditions
Environmental Conditions For Storage
The device complies with class 1K5 as per IEC 60721-3-1 (climatic conditions):
The device complies with class 1M2 as per IEC 60721-3-1 (mechanical conditions):
Environmental Conditions For Transportation
The device complies with class 2K5H as per IEC 60721-3-2 (climatic conditions):
The device complies with class 2M2 as per IEC 60721-3-2 (mechanical conditions):
Characteristic Value
Ambient temperature -40 ... 70 °C (-40 ... 158 °F)
Rate of change of temperature 1 °C/min (1.8 °F/min)
Ambient humidity 10 ... 100 % relative humidity
Characteristic Value
Vibration, sinusoidal, displacement amplitude
2 ... 9 Hz
1.5 mm
Vibration, sinusoidal, acceleration amplitude
9 ... 200 Hz
5 m/s
2
Shock, shock response spectrum type L, peak
acceleration
40 m/s
2
Characteristic Value
Ambient temperature -25 ... 85 °C (-13 ... 185 °F)
Change of temperature, air/air -25 ... 30 °C (-13 ... 86 °F)
Ambient humidity 5 ... 95 % relative humidity, no condensation
Characteristic Value
Vibration, sinusoidal, displacement amplitude
2 ... 9 Hz
3.5 mm
Vibration, sinusoidal, acceleration amplitude
9 ... 200 Hz
10 m/s
2
Vibration, sinusoidal, acceleration amplitude
200 ... 500 Hz
15 m/s
2
Shock, shock response spectrum type I, peak
acceleration
100 m/s
2
Shock, shock response spectrum type II, peak
acceleration
300 m/s
2