Step 6 settings
Function Device Address Setting Value Details
Steady pulse frequency D0042, D0043 15 15 Hz
Frequency change time D0045 5000 5000 ms
Preset value D0046, D0047 30000 Preset value=30,000
Control direction D0048 — —
Acceleration/deceleration control D0048 Acceleration/deceleration first Before=0
Next step number D0049 0 0=End output