10. Troubleshooting
Fault Check Cause Solution
Themotordoesnot
startafteractivating
thestargrip.
Themainswitch
isnotilluminated,
althoughithasnot
beenswitchedo󰀨.
Thestargripwas
notusedforsome
time(atleast10
minutes)during
batteryoperation.
Therechargeable
batteryhas
switcheditselfo󰀨.
Inordertoresume
workwiththedevice,
theeDRAULIC
devicemustrst
beswitchedo󰀨at
themainsandthen
switchedonagain.
Alternatively,the
capacitydisplayon
therechargeable
batterycanbe
activatedorthe
batterymaybe
brieyunplugged
andreplugged
again.
Bladearmsmove
slowlyorjerkily
whenoperated
Batteryfully
charged?
Batteryat Chargebattery
Batterydefective Replacebattery
Airinthehydraulic
system
Repairbyan
authorizeddealer,by
personnelspecially
trainedbyHURST,
orbyHURSTitself
Powersupplycable
connected?
Powersupply
notproperly
connectedtothe
eDRAULICdevice
(notautomatically
locked).
Reinsertpower
supplyintothe
connectionshaft
Powersupply
cablenotproperly
connectedtothe
externalpower
supply.
Reconnectexternal
powersupply
Powersupplyor
powersupplycable
defective.
Replacepower
supplyorpower
supplycable
Externalpower
sourcedefective.
Useotherexternal
powersource