EasyManua.ls Logo

Idex HURST eDRAULIC SC 258 E2 - Edraulic Combination Device

Default Icon
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
11.1 eDRAULIC combination device
Device type SC 258 E2 SC 358 E2
Item number 273028000 273023000
Dimensions (excluding Battery)
LxWxH
[mm] 874x215x281 956x237x281
[in.] 34.4 x 8.46 x 11.1 37.7 x 9.3 x 11.1
Min. cutting opening
[mm] 233 309
[in.] 9.2 12.2
Max. cutting force
(rearmostcuttingpoint)
[kN] 280 492
[lbf.] 63000 110600
Minimum spreading force
(atadistanceof25mm/
0.98inchesfromthetips)
[kN] 32 38
[lbf.] 7200 8543
LSF spreading force
(accordingtoNFPA)
[kN] 24 33
[lbf.] 5400 7419
HSF spreading force
(accordingtoNFPA)
[kN] 29 43
[lbf.] 6500 9667
Max. possible spreading force
[kN] 700 1500
[lbf.] 157000 337230
Maximum spreading path
[mm] 321 372
[in.] 12.6 14.7
Maximum pulling force
(withapprobiatechainset)
[kN] 34 61
[lbf.] 7640 13714
Pulling path
(withapprobiatechainset)
[mm] 330 382
[in.] 13.0 15
HPF pulling force
(accordingtoNFPA)
[kN] 37 62
[lbf.] 8320 13940
LPF pulling force
(accordingtoNFPA)
[kN] 28 43
[lbf.] 6300 9667
Mass (excl. battery)
[kg] 14,9 18,7
[lbs.] 32.8 41.2
Nominal electrical voltage
(withpowersupply)
[V DC] 25 25
Nominal electrical voltage
(withlithium-ionbattery)
[V DC] 25,2 25,2
Protection category
IP54 IP54
Cutting Class F I
Classication (NFPA 1936) A6/B6/C6/D7/E7 A7/B8/C7/D8/E7