Function
Parameter
Description
Stay & Go
Prof3
Partition
Number
Will arm the allocated partition in stay & Go in stay profile 3 and then allow
you to scroll to the next available profile if one is configured.
Stay & Go
Prof4
Partition
Number
Will arm the allocated partition in stay & Go in stay profile 4 and then allow
you to scroll to the next available profile if one is configured.
Duress Disarm
Partition
Number
Will disarm the allocated partition and cause a duress condition in the
alarm system and if configured the alarm will transmit the duress signal to
the security company.
Panic
Partition
Will cause the alarm to go into a panic condition and if configured the
alarm will transmit the panic signal to the security company.
Medical
Partition
Will cause the alarm to send a medical alert signal to the security
company if configured.
Fire
Partition
Will cause the alarm to send a fire alert signal to the security company if
configured.
PGM Low
PGM
Number
Will trigger the specified programmable output depending on the type of
output, to switch from 12V to 0V or from a closed state to an open state.
PGM High
PGM
Number
Will trigger the specified programmable output depending on the type of
output, to switch from 0V to 12V or from an open state to a closed state.
PGM PulseL
PGM
Number
Will trigger the specified programmable output depending on the type of
output, to switch from 12V to 0V and back to 12V or from a closed state to
an open state and back to a closed state. (Pulse length setup under the
output properties.)
PGM PulseH
PGM
Number
Will trigger the specified programmable output depending on the type of
output, to switch from 0V to 12V and back to 0V or from an open state to
a closed state and back to an open state. (Pulse length setup under the
output properties.)
PGM Toggle
PGM
Number
Will trigger the specified programmable output depending on the type of
output, to the opposite of its current state. If at 0v will set to 12v, if at 12v
will set to 0v. Toggling the PGM.
3.5. Deleting Remote Transmitters
If a remote transmitter is lost or no longer used follow the following steps to delete the remote
transmitter from the system.
1. Enter the Master User Menu
2. Scroll to menu [Delete BD Remote] or enter [1][8][*]
3. Enter the Hub that the remote belongs too
4. Enter the user code that was paired with the remote
3.6. Remote Transmitter LED
The remote transmitter has bi-directional communication with the X-Series alarm panel and will
display different information by changing the colour of the LED and flashing a number of times.
The remote transmitter will respond with the status when you use a button or you can query the
alarm panel and get feedback e.g. armed or disarmed, current stay profile, outputs.
To query status:
1. Press the function button. (Button 1)
2. Then press the button that is allocated to the function that is being queried
3. The LED will indicate the status.