The charged particles are precipitated on the precipitation electrodes and thus divided
for the air current. The bigger the difference of charge is between the aluminium plates
and the particles, the more effective the precipitation will be. Gravity will make the
particles of the cooling agents that are deposited on the vertical electrodes drain into the
reservoir, unless the particles get solidly.
Filter stage 4
The last element is a metal filter that is responsible for a good distribution of air.
2.3 Required space
The IFE - electronical precipitation engine (Type IFE 2000) can be run for a direct
sucking off at the spot. Besides it can be used as a filter for circulating air when placed
at the sheds ceiling. Other places of installation for this use cover the use at the sheds
side walls and any other place indoor when placed on a rack.
This allows short tubes to retrace the clean air into the production sheds.