EasyManua.ls Logo

iGenix IG9901WIFI - Fan Speed and Oscillation Control; Mode Explanations and Additional Functions

iGenix IG9901WIFI
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Turning Off
• Press the “POWER” button to switch off the appliance
Modes - Explained:
Auto Mode: The appliance will automatically adjust the functions by either selecting the Cooling or
Fan mode, based on the following principles:
• When the room temperature is ≥ 24°C, Cooling mode is selected
• When the room temperature is < 24°C, Fan mode is selected
Dehum. Mode: The fan will operate at low speed (Fan Speed cannot be adjusted in Dehum. Mode)
and then the compressor will be activated. In dehumidifying mode, the appliance will run through a
repeated cycle sequence of:
• 8 minutes both compressor and fan operation
• 6 minutes fan only operation
The appliance adopts a constant temperature, which cannot be manually adjusted.
Note: To turn off the Dehumidifying function you can either select a different mode or press the on/off
button.
Cooling Mode: Self Evaporating Air Conditioning mode activated:
• When the ambient room temperature is higher than the desired room temperature, the compressor
will operate.
• When the ambient room temperature is lower than the desired room temperature, the compressor
will stop and the fan will operate at the selected speed.
Fan Mode:
• The fan will operate at the desired speed.
• (The compressor will not run in this mode)
Note: Temperature cannot be adjusted in Fan Mode
Additional Functions
Timer: The timer can be set between 1 to 24 hours by increments of 1 hour; turning the appliance
either on or off.
• To set Automatic time off (whilst unit is running). Press the “Timer” button and then press
the “ ” or “ ” buttons
• To Set Automatic time on (whilst unit is in standby). Press the “Timer” button and then press
the “ ” or “ ” buttons
Sleep Mode: This operation can only be selected when in Cooling Mode.
• Press the “Sleep” button when in cool mode, the fan will automatically turn down to low fan speed.
The appliance will then operate the following sequence:
• The set temperature will increase by 1°C after 1 hour, then increase by 2°C after 2 hours.
After 6 hours the appliance will automatically switch off.
Adjust Fan Speed
• Press the “Fan” button to select the desired fan speed shown below:
Oscillation Function
• Press the “OSCIL” button to select the horizontal louvres to automatically move up and down
• Press the “OSCIL” button again to switch off this function