FINAL PREPARATION
Continued
INSTALLING HOOD(S)
Hood Screw Locations
FRONT VIEW
SIDE VIEW
Hood
(Deflector Facing Downward)
Hood Detail
End View
The fireplace requires hoods to be installed into the upper opening of the firebox. If you are installing a single-sided fireplace you only in-
stall one (1) hood. NOTE: If you are installing a see-through fireplace a hood is required on both sides of the fireplace opening. All models
require five (5) screws to secure the hood to the fireplace except the 72-inch model, which uses seven (7) screws to secure the hood. The
hood protrudes 1-inch from fireplace opening.
Figure 37 Shows hole location and installation process for hood installation. The protruding area of the hood is to be angled downward
for proper installation, see Hood Detail below.
Figure 37 - Installing hood(s) on the fireplace
GLASS WINDSHIELD
Side View
Installing Glass
Rotate top
clip to a 45°
angle
Glass Windsheid
Installed
1
2
3
Side View
Rotate Top Clip
LED Channel
Cover
INSTALLING WINDSHIELD(S)
Before installing the windshields first rotate the top windshield clip
to approximately 45°. See Figure 38. Next while holding the glass
panel horizontally slide the bottom end on each side into the top
windshield clip. Then slide the entire windshield down into the lower
clip and rest on top of the LED channel cover.
Figure 38 - Installing glass windshield into fireplace