Installation Draco tera IP Gateway
28
6.2.6 Connecting to the Matrix via Device Finder
At least power user rights are required, and the API function have to be enabled.
Up to 16 connections between the matrix and the management software can be established at the same time due
to a limitation of available sockets.
The Device Finder offers the possibility to find all matrices that are in the same subnet. This is useful, e.g., if the IP
address of a specific matrix is unknown and should be accessed via IP.
Fig. 11 Management software menu Device Finder
The following device information is shown in the Device Finder:
Information Description
Broadcast/Multicast Search parameters for finding devices.
Search via broadcast: 255.255.255.255 (default).
Input for search within a multicast group: multicast address
Device Name of the device
Name Name of the active configuration
IP Address Current IP address of the device
MAC Address MAC address of the device
Type Type of the device
The last column of the Device Finder can be used to connect to the respective matrix directly clicking Connect.