EasyManua.ls Logo

Ihse Draco tera enterprise 480 Series - User Manual

Ihse Draco tera enterprise 480 Series
401 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Document 480-xx_REV01.00_en
Edition: 2022-02-28
USER MANUAL
Draco tera
enterprise
KVM Matrix Switch
Series 480

Table of Contents

Other manuals for Ihse Draco tera enterprise 480 Series

Questions and Answers

  • D
    Darius SantiagoAug 8, 2025
    What to do if the Ihse Switch matrix cannot be started?
    • B
      Brian TuckerAug 8, 2025
      If your Ihse Switch matrix fails to start, verify that the power supply units are correctly locked and plugged in. Also, ensure the power supply cables are properly connected and the power supply units are switched on.
  • J
    joseph93Aug 13, 2025
    Why is there an incorrect video display on my Ihse Switch?
    • B
      brittanytaylorAug 13, 2025
      If you experience an incorrect video display with your Ihse Switch, check the connection, length, and quality of the interconnect cable to the units. A disturbed cable connection can cause this issue.
  • P
    peterserinAug 17, 2025
    How to check the fuse on the Ihse Draco tera enterprise 480 if the matrix cannot be started anymore?
    • B
      benjamin57Aug 17, 2025
      If the Ihse Switch matrix can no longer be started, check the fuse at the standard appliance outlet. A blown fuse could be the cause.
  • J
    Jennifer HarrisAug 21, 2025
    What to do if Ihse Draco tera enterprise 480 fans do not run, and the LED OK is off?
    • N
      nguyendorisAug 21, 2025
      If the fans on your Ihse Switch do not run, and the LED OK is off, check the power supply and power connection. This indicates a potential power supply issue.
  • S
    Sheila RodgersAug 25, 2025
    Why are network settings not assumed after editing on my Ihse Draco tera enterprise 480 Switch?
    • K
      Kathy MorganAug 26, 2025
      If network settings are not applied after editing your Ihse Switch, restart the matrix. The restart may not have been completed.
  • A
    Aaron ReyesAug 30, 2025
    What to do if Ihse Draco tera enterprise 480 Switch fans only run under full load?
    • M
      Matthew Ross MDAug 30, 2025
      If the fans on your Ihse Switch only run under full load: 1. Remove and reinstall the fan tray, because communication to fan tray might not be working. 2. Swap both fan trays to the other slot. 3. Restart the matrix.
  • N
    Nathaniel VillegasSep 3, 2025
    How to fix the issue of not being able to open the OSD on Ihse Switch?
    • P
      Peter ClaySep 3, 2025
      If you cannot open the OSD on your Ihse Switch, set jumper 11 on the CON Unit. This issue occurs when no OSD jumper is set.

Ihse Draco tera enterprise 480 Series Specifications

General IconGeneral
ModelDraco tera enterprise 480 Series
CategorySwitch
Ports480
TypeMatrix Switch
Video FormatsHDMI, DisplayPort, DVI, SDI
Audio FormatsEmbedded audio, analog audio
ControlWeb interface, serial interface, API