7.9 Configuring Matrix Cascading
This simple method of cascading allows a switchable connection between two matrices via so called Tie
Lines. The Matrix Cascading does not require Bundle 4.
This kind of configuration may become necessary if the number of ports in the entire system has to be
increased or if certain important connections should be distributed to several matrices due to reasons of
redundancy.
The Tie Lines are unidirectional and can only be used in one direction according to their configuration. For
a bidirectional use of the cascading, you have to configure opposite Tie Lines.
To connect Tie Lines to the matrices, you first have to create intended Cascade CON Devices and
Cascade CPU Devices that have to be switched within the cascaded environment.
Ensure that the Tie
Lines will only be connected after finishing the configuration.
Activating the Sub Matrix Option
1. Connect to the defined Sub Matrix and click Activate Edit Mode in the toolbar.
2. Click System Settings > System in the task area of the Sub Matrix.
3. Tick the Sub Matrix checkbox in the working area.
4. Click Apply to confirm the Sub Matrix option.
The OSD of the Sub Matrix will immediately freeze and will be only accessible by using the keyboard
command
Hot Key, s, o.
5. Click Deactivate Edit Mode in the toolbar.
Fig. 179 Management software menu System Settings > System