4 - 12 4. SETTINGS
BS-79 BS-79 0212 VOL1 (U) (E)
4.7 Interchanging the ENG and PROD Intercom Systems
Caution: Be sure to place switches S1 and S2 to the same position.
ENG/ENG : Normal position. The ENG system is connected to the ENG system and the PROD system is connected
to the PROD system.
ENG/PROD : For the system, the ENG system is connected to the PROD system and the PROD system is connected
to the ENG system.
AUDIO module
ENG/
ENG
S1
ENG/
PROD
ENG/
ENG
S2
ENG/
PROD