B6 incorporates a variety of functions for the systems to verify processes
and the state of the electronics. In case of an error the screen will display
the cause of error and emit an audible sound.
REVERSE POLARITY
CONNECTION BREAK
SHORT ERR
INPUT VOL ERR
VOL SELECT ERR
BREAK DOWN
BATTERY CHECK
LOW VOLTAGE
BATTERY CHECK
HIGH VOLTAGE
BATTERY VOLTAGE
CELL LOW VOL
BATTERY VOLTAGE
CELL HIGH VOL
BATTERY VOLERR
CELL CONNECT
TEMP OVER ERR
CONTROL FAILURE
Incorrect polarity connected.
Battery connection is interrupted.
Short-circuit of the output termination.
Erroneous selection of voltage of Lithium
pack, please check the voltage of the battery
pack.
The voltage of the battery pack has been
selected incorrectly!
The charger has malfunctioned for some
reason. Seek professional advice.
The voltage is lower than which is set. Please
check the number of cells in the battery pack.
The voltage is higher than which is set. Please
check the number of cells in the battery pack.
Voltage of one cell in the battery pack is too
low, please check the voltage of each cell.
Voltage of one cell in the battery pack is too
high; please check the voltage of each cell.
Wrong connection of the connector detected;
please check the connector and cable.
The internal temperature is too high, please
cool down.
The processor cannot control the feeding
current, please repair it.