18
Chapter 7 GUIDE TO RECOGNISING DAMAGE AND ANOMALIES
This chapter presents and discusses all the simple problems which could occur during machine use.
The appropriately qualified, professional personnel must carry out all the maintenance procedures, check and control,
as well as all the repair operations on parts of the machine or the electrical system.
Contact Technical Sales Assistance for any other problem not listed on the previous table or should the malfunctioning
persist after the intervention of the operator in accordance with the previously mentioned courses of action.
FAILURE POSSIBLE CAUSE CURE
Verify the correct use of the Main Switch
(C4)
No supply
Verify the Main in the control panel
After operating the Main
Switch, The machine does
not start.
Fuses are broken
Replace the fuses with the new fuses
having the same capacity. The fuses are
on the electronic card inside the switch
board.
Failure to the electric system
Check if the wires and the connections of
the electric circuit are interrupted.
After a correct set up of the
sieve shaker, pressing the
button (C11) the electro
magnet does not work
Failure to the electromagnet Contact our After Sale Service
Chapter 8 SPARE PARTS AND ACCESSORIES
WARNING
DANGER
Only original spare parts can be used.
Use of unoriginal spare parts exempts the manufacturer from all responsibility.
Procedures for substitution of spare parts will be provided by the manufacturer
along with the part. For spare parts contact the manufacturer’s Sales Service
department.
NOISE REDUCTION CABINET
Cabinet lined internally with sound-proofing material for noise reduction to CE Directive.
KNOB
Knob for fast clamping/release of the upper beam.
Useful for fast vertical displacement of the beam.
Pack of 2 knobs.