EasyManua.ls Logo

Infiniton CMPY-IST9A - Page 24

Infiniton CMPY-IST9A
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
inniton.es
8
Hints for exhaust duct installation
The following rules must be strictly followed to obtain optimal air extraction:
• Keep exhaust duct short and straight
• Do not reduce the size or restrict the exhaust duct
• When using the exible duct always install the duct pulled taut to minimize pressure loss
• Failure to observe these basic instructions will reduce the performance and increase noise levels of
the range hood.
• Any installation work must be carried out by a qualied electrician or competent person.
• Do not connect the ducting system of the hood to any existing ventilation system which is being
used for any other appliance ,such as warmer tube, gas tube , hot wind tube.
• The angle of the bend of the ventilation pipe should not be less than 120º; you must direct the pipe
horizontally, or, alternatively, the pipe should go up from the initial point and should be led to an
outer wall.
• After the installation ,make sure that the cooker hood is level to avoid grease collection at on end.
Note: Ensure the exhaust ducting selected for installation complies with relevant standards and is re
retardant
For safety reason, please use only the same size of xing or mounting screws
which are recommended in this instruction manual.
Failure to install the screws or xing device in accordance with these
instructions may result in electrical hazards.
WARNING!
English
Installation
inniton.es