12 13
Test Strip Information
Before Testing - Setting the Meter
Important
power on
Press for 3 seconds at least
The EASYGLUCO Auto-coding
TM
has a variety of excellent functional
modes and options:
Up to 5 alarms at planned testing times, unique User ID option, ability to
designate activities related to the test result, and the ability to designate three
different numbers of days for average calculation.
User Activity option
After pressing and releasing either Ƈ or Ɖ
buttons to turn the user Activity option on/off,
confirm with .
User ID option
After pressing and releasing either Ƈ or Ɖ
buttons to turn User ID option on/off, confirm with
.
Limitations of Blood glucose measuring system :
The blood glucose test Strips provide accurate results when the following
constraints are observed :
- Use the blood glucose test strips with the
blood glucose test meter or
blood glucose test meter.
- Use fresh capillary whole blood only.
- Do not use neonate samples.
- The blood glucose test strips are for single use only. Do not reuse.
- Dehydration may lower test results.
- Inaccurate results may occur when in shock, hypotensive, hyperglycemic, or hyperosmolar
state, with or without ketosis.
- Blood glucose test strips used above altitudes of 10,000 feet will have an effect on test results.
Doctors - Please note the following interferences that may affect test results :
- test strip results can be used with hematocrit levels in
the range of 20% to 60%. If the hematocrit range is out of the range(20%~60%), then the
test results may be lower or higher than actual value.
- If you do not know your hematocrit level, consult your healthcare professionals.
- Interferences : Acetaminophen, Uric and, Ascorbic acid (Vitamin C), and other reducing
substances when occurring in normal blood or normal therapeutic concentrations
do not significantly affect results. However, abnormally high concentrations in may
cause inaccurately high results.
- Lipemic samples; Cholesterol up to 500 mg/dL or triglyceride up to 3000 mg/dL do
not significantly affect the results. Values beyond these levels should be interpreted
with caution.
- Blood samples that contain a high concentration of dissolved oxygen may lower the
test result.
Performance Characteristics :
The performance of the blood glucose test strips has been evaluated in laboratory and
in clinical tests.
Note : For detailed performance results, please refer to
strip instruction for use
Measurement Range : The measurement range of the
Blood glucose measuring system is 10 to 600 mg/dL.