EonStor DS S12/S16/S24 Series Hardware Manual
Single controller model: 350W; idle: 261.9W; Busy: 284.8W
DC Output 12.0V: 28A (Max.)
5.0V: 43A (Max.)
Input Frequency 47 to 63Hz
AC Input 100VAC @ 10A or 240VAC @ 5A with PFC
Power Factor Correction Yes
Hold-up Time At least 16ms at 115/230VAC full load after a loss of AC input
I
2
C Through backplane to controller
Over-temperature
Protection
Auto shutdown when lost cooling or exceeded ambient temperature;
over-voltage protection is also available.
S24 Series
Input Voltage 100VAC @ 8A to 240VAC @ 4A with PFC (auto-switching)
Frequency 50 to 60 Hz
Power consumption 434W busy; 408.9W idle
6.1.5 Dimensions
S12 series
Dimensions Without chassis ears &
protrusions
With chassis ears & protrusions
Height 88mm 89mm
Width 446mm 481.6mm
Length 514mm 531.6mm
S16 series
Dimensions Without chassis ears &
protrusions
With chassis ears & protrusions
Height 130mm 131mm
Width 445mm 482.6mm
Length 514.04mm 531.64mm