EonStor DS S12/S16/S24 Series Hardware Manual
3.7 Management Console Connections
You will need the following cables for connecting the RAID system with external
consoles.
Serial port: For dual-controller models, a Y-cable is provided in the package. For
single-controller models, a standard DB9 straight cable (no null modem required)
should be supplied by the user.
LAN port: A LAN cable should be supplied by the user.
The serial port’s defaults are:
Baud Rate 38400
Data Bit 8
Parity None
Stop Bit 1
Flow Control Hardware
For TCP/IP connection and firewall configuration with a management station running
SANWatch, please refer to SANWatch’s online help or User’s Manual. If your
environment has no DHCP server, a default IP, <10.10.1.1> can be used to make an
access for the first time.