226
X
trapulsPac – User Guide
Chapter 3 - Referenc
Update Interface
General Commands
Index 0x5F30
Name Update
Object Code RECORD
Number of Elements 5
Value Description
Sub Index 1
Description Update_Code
Data Type Unsigned16
Access rw
Value Write: Select firmware_Code (> 0)
Read back: same code = Update_Code supported, 0 if not supported
Sub Index 2
Description Update_Mode
Data Type Unsigned16
Access rw
Value Write signature: 0x00000001
Change to update mode, Update_Code must be <> 0
depend on Update_Code, the execution time of this instruction may be very long:
for example: update firmware -> switch from firmware mode to bootmanager mode
Update Init
Index 0x5F31
Name Update Init
Object Code RECORD
Number of Elements 5
Sub Index 1
Description Number of Binary Blocks
Data Type Unsigned16
Access rw
Value
Sub Index 2
Description Number of Block Types
Data Type Unsigned16
Access rw
Value
Sub Index 3
Description Sectors
Data Type Unsigned32
Access rw
Value Each bit = 1 sectors
support up to 32 sectors
Sub Index 4
Description Erase Command
Data Type Unsigned32
Access rw
Value Signature = 0x00000001
the execution time of this instruction is very long