3 4 IDS404 INSTALLER MANUAL NO. 700-277-02A ISSUED SEPT 2004 VER 1.02
IDS404 INSTALLER MANUAL
Locations 68 - 83 : Primary Phone Number
Locations 84 - 99 : Secondary Phone Number
! If dual reporting is selected, program the following locations:
Locations 60 - 63 : Primary Account Code
Location 64 : Primary Communicator Format
Locations 68 - 83 : Primary Phone Number
Locations 84 - 99 : Secondary Phone Number
Locations 172 - 175 : Secondary Account Code
Location 176 : Secondary Communicator Format
! If both phone numbers are to use the same communicator format
and account codes then locations 60 - 64 must be programmed
with the same values as locations 172 - 176.
95-85SNOITACOL devreseR
36-06SNOITACOLedoCtnuoccArotacinummoCyramirP
The four digit account code for the telephone communicator is
programmed into these locations. The panel is identified at the receiver
by this account number.
! The account code must be four digits long. Any account number
shorter than four digits must be preceded with “10”s.
! When programming locations 60-63 a [0] must be entered as
a [10]
The following table provides the conversion between the hexadecimal
value and the value programmed into a particular location.
eulaVlaciremuN
123456789 011121314151
eulaVlamicedaxeH
123456789ABCDEF
Example: The desired account code is 14 (i.e. 0014)
1. Enter [10] into location 60.
2. Enter [10] into location 61.
3. Enter [1] into location 62.
4. Enter [4] into location 63.